Gaggenau AL400721 Folleto
86
Vario cooktops
V I 461 110
Stainless steel frame
Width 60 cm
Width 60 cm
Installation accessories
V A 420 010
V A 420 010
Connection strip for combination with
other Vario appliances of the 400
series for surface installation
other Vario appliances of the 400
series for surface installation
V A 420 011
Connection strip for combination with
other Vario appliances of the 400
series for surface installation with
appliance cover/adjustment strip
other Vario appliances of the 400
series for surface installation with
appliance cover/adjustment strip
V A 420 000
Connection strip for combination with
other Vario appliances of the 400
series for flush installation
other Vario appliances of the 400
series for flush installation
V A 420 001
Connection strip for combination with
other Vario appliances of the 400
series for flush installation with
appliance cover/adjustment strip
other Vario appliances of the 400
series for flush installation with
appliance cover/adjustment strip
V A 450 600
Stainless steel adjustment strip 60 cm
Required accessory for combination of
several Vario appliances of the 400
series with at least one appliance cover
to compensate the appliance depth.
Required accessory for combination of
several Vario appliances of the 400
series with at least one appliance cover
to compensate the appliance depth.
Vario induction cooktop 400 series
V I 461
– Three cooking zones with booster
for cookware with a diameter of
15 to 28 cm
15 to 28 cm
– Solid stainless steel control knob
– Precision crafting of 3 mm stainless
steel
– For surface installation with a
visible edge or for flush installation
– Can be combined perfectly with
other Vario appliances of the 400
series
series
Cooking zones
1 induction cooking zone ø 18 cm
(1,800 W, with booster 2,500 W),
automatically switches to ø 28 cm
(2,800 W, with booster 4,400 W).
1 induction cooking zone ø 21 cm
(2,200 W, with booster 3,300 W).
1 induction cooking zone ø 15 cm
(1,400 W, with booster 1,800 W).
(1,800 W, with booster 2,500 W),
automatically switches to ø 28 cm
(2,800 W, with booster 4,400 W).
1 induction cooking zone ø 21 cm
(2,200 W, with booster 3,300 W).
1 induction cooking zone ø 15 cm
(1,400 W, with booster 1,800 W).
Handling
Control knobs with illuminated ring,
cooking zone and output level
markings.
Electronic control in 12 output levels.
cooking zone and output level
markings.
Electronic control in 12 output levels.
Features
Cooking zone marking.
Booster function for each cooking
zone.
Super booster function for ø 28 cm
cooking zone.
Pot detection.
Timer.
Booster function for each cooking
zone.
Super booster function for ø 28 cm
cooking zone.
Pot detection.
Timer.
Safety
Individual residual heat indicators.
Safety shut-off.
Safety shut-off.
Planning notes
Depending on the type of installation
(surface-mounted or flush-mounted,
with or without an appliance cover), the
specific location of the cut-out and the
knob positions may vary.
If installing with the appliance cover
VA 440 or adjustement strip VA 450
take into account the additional space
required for the depth.
If combining several appliances with at
least one appliance cover, the
adjustment strip VA 450 is required to
compensate for the depth of the
appliance without the appliance cover.
If combining several Vario appliances
of the 400 series, a connection strip
VA 420 must be placed between the
appliances. Depending on the type of
installation, the corresponding
connection strip must be provided.
In the cut-out, the installation system
requires the side edge to be at least
10 mm for surface installation and at
least 13 mm for flush installation.
Ensure a continuous cut surface of
90°.
The bearing capacity and stability, in
the case of thin worktops in particular,
must be supported using suitable
substructures. Take into account the
appliance weight and additional loads.
Additional instructions for flush installa-
tion:
Installation is possible in worktops
made of stone, synthetics or solid
wood. Heat resistance and watertight
sealing of the cut edges must be
observed. Concerning other materials
please consult the worktop manu-
facturer.
(surface-mounted or flush-mounted,
with or without an appliance cover), the
specific location of the cut-out and the
knob positions may vary.
If installing with the appliance cover
VA 440 or adjustement strip VA 450
take into account the additional space
required for the depth.
If combining several appliances with at
least one appliance cover, the
adjustment strip VA 450 is required to
compensate for the depth of the
appliance without the appliance cover.
If combining several Vario appliances
of the 400 series, a connection strip
VA 420 must be placed between the
appliances. Depending on the type of
installation, the corresponding
connection strip must be provided.
In the cut-out, the installation system
requires the side edge to be at least
10 mm for surface installation and at
least 13 mm for flush installation.
Ensure a continuous cut surface of
90°.
The bearing capacity and stability, in
the case of thin worktops in particular,
must be supported using suitable
substructures. Take into account the
appliance weight and additional loads.
Additional instructions for flush installa-
tion:
Installation is possible in worktops
made of stone, synthetics or solid
wood. Heat resistance and watertight
sealing of the cut edges must be
observed. Concerning other materials
please consult the worktop manu-
facturer.
The groove must be continuous and
even, so that uniform placing of the
appliance on the gasket is ensured.
Do not use discontinuous lining.
The joint width may vary due to size
tolerances of the combinations and of
the worktop cut-out.
even, so that uniform placing of the
appliance on the gasket is ensured.
Do not use discontinuous lining.
The joint width may vary due to size
tolerances of the combinations and of
the worktop cut-out.
Please read additional planning notes
on page 116–123 .
on page 116–123 .
If installing several appliances in
individual cut-outs allow for a division
bar of minimum 50 mm between the
individual cut-outs.
Operates with magnetic (induction)
iron pots and pans only. For an optimal
heat distribution, the use of sandwich
bottom cookware is recommended.
The wok pan WP 400 001 cannot be
used with this appliance.
Immersion depth depending on
installation situation 54/57 mm.
Built-in control panel to be integrated
in the bottom cabinet at drawer level.
Panel thickness 16 – 26 mm.
The drawing "Installation of the control
knob" must be observed if the panel is
more than 26 mm thick (there must be
a recess at the rear).
Appliance can be snapped into the
worktop from above.
Appliance weight: approx. 14 kg.
Please read additional planning notes
on page 178 .
individual cut-outs allow for a division
bar of minimum 50 mm between the
individual cut-outs.
Operates with magnetic (induction)
iron pots and pans only. For an optimal
heat distribution, the use of sandwich
bottom cookware is recommended.
The wok pan WP 400 001 cannot be
used with this appliance.
Immersion depth depending on
installation situation 54/57 mm.
Built-in control panel to be integrated
in the bottom cabinet at drawer level.
Panel thickness 16 – 26 mm.
The drawing "Installation of the control
knob" must be observed if the panel is
more than 26 mm thick (there must be
a recess at the rear).
Appliance can be snapped into the
worktop from above.
Appliance weight: approx. 14 kg.
Please read additional planning notes
on page 178 .
Connection
Total connected load 7.2 kW.
Connecting cable 1.5 m without plug.
Connecting cable 1.5 m without plug.