Replacing Nozzles
The burners can be adapted to suit different  types of gas by fitting the nozzles that correspond to the gas
used.  To do this, it is necessary to remove the burner heads and use a straight key "B", to unscrew the
nozzle "A" (see Fig. 7) and replace it with a nozzle corresponding to the gas used.
Be sure the nozzle is seated tightly.
After making these replacements, the technician must regulate the burners as described in
Adjustments on the previous page and apply the label corresponding to the new gas type in place
of that previously applied.  This label is contained in the spare nozzle bag.
How to change the setting of the pressure regulator supplied with the cooktop: 
The gas regulator was set up to Natural Gas. To convert to LP Gas:
1.  Unscrew the aluminum cap
2.  Remove and turn the plastic pin 180° 
3.  Screw in the plastic pin
4.  Screw in the aluminum cap 
For ease of the fitter, we have prepared a table indicating the flow capacities, the heat capacities of the
burners, the diameter of the nozzles and the working pressure for the various types of gas. 
CONVERSIONS
FIG. 7