3COM
®
SWITCH S7900E FAMILY
Switch S7902E
Height: 17.5 cm (6.9 in)
Width: 43.6 cm (29.2 in)
Depth: 42.0 cm (16.7 in)
Weight: 27 kg (59 lb)
POWER SUPPLIES
2800W AC Power Supply
Input voltage: 100V to 240V auto ranging
Operating frequency: 47-63 Hz
Max. data output: 1,150W (110V), 1,400W (220V)
Max. PoE output: 1,150W (110V), 1,400W (220V)
Two power cords
Max. current per power cord: 10.45 A at 110VAC, 7.0 A at 200 VAC
1400W AC Power Supply
Input voltage: 100V to 240V auto ranging
Operating frequency: 47-63 Hz
Max. data output: 1150W (110V), 1400W (220V)
Max. current: 10.45A at 110VAC, 7.0A at 200 VAC
Data only
650W AC Power Supply
Input voltage: 100V to 240V auto ranging
Operating frequency: 47-63 Hz
Max. data output: 650W
Max. current: 5.9A at 110VAC, 3.25A at 200 VAC
Data only
1400W DC Power Supply
Input voltage: -48 VDC to -60VDC
Max. voltage range: -40VDC to -72VDC
Max. output power: 1400W
Can be used for data or PoE
650W DC Power Supply
Input voltage: -48 VDC to -60VDC
Max. voltage range: -40VDC to -72VDC
Max. output power: 650W
Data only
ENVIRONMENTAL REQUIREMENTS
Operating temperature: 0°to 40°C (32°to 104°F)
Storage temperature: -10°to 70°C (14°to 158°F)
Humidity (operating and storage): 10% to 90% non-condensing
Heat dissipation
Switch S7910E : 4,148 BTU/hr
Switch S7906E: 2,746 BTU/hr
Switch S7906E-V: 2,765 BTU/hr
Switch S7903E: 1,651 BTU/hr
Switch S7902E: 883 BTU/hr
IEEE STANDARDS SUPPORTED
IEEE 802.1D (STP)
IEEE 802.1p (COS)
IEEE 802.1Q (VLAN)
IEEE 802.1s (MSTP)
IEEE 802.1v (VLAN)
IEEE 802.1w (RSTP)
IEEE 802.1X (Security)
IEEE 802.3ab (1000BASE-T)
IEEE 802.3ad (Link aggregation)
IEEE 802.3ae (10GBASE-X)
IEEE 802.3af (PoE)
IEEE 802.3i (10BASE-T)
IEEE 802.3u (Fast Ethernet)
IEEE 802.3x (Flow control)
IEEE 802.3z (Gigabit)
IETF STANDARDS
RFC 768 (UDP)
RFC 791 (IP)
RFC 792/950 (ICMP)
RFC 793 (TCP)
RFC 826 (ARP)
RFC 919/922 (Broadcasting Ethernet Datagrams)
RFC 950 (IP subnetting)
RFC 951 (BOOTP)
RFC 959/2228 (FTP)
RFC 1058 (RIP)
RFC 1112 (IGMP v1)
RFC 1122 (IP Host Requirements
RFC 1141 (Internet Checksum)
RFC 1142 (OSI IS-IS)
RFC 1195 (IS-IS)
RFC 1256 (ICMP Router Discovery)
RFC 1305 (NTP)
RFC 1350 (TFTP)
RFC 1518/1519 (CIDR)
RFC 1542 (BOOTP)
RFC 1587/3101 (OSPF NSSA)
RFC 1723/2453 (RIP v2)
RFC 1765 (OSPF Database overflow)
RFC 1771 (BGP-4)
RFC 1812/2644 (IPv4)
RFC 1881/1887 (IPv6 Address Allocation)
RFC 1965/3065 (BGP AS Confederation)
RFC 1981 (Path MTU discovery for IPv6)
RFC 1997/1998 (BGP Communities)
RFC 2080 (RIPng)
RFC 2082 (RIP v2 MD5 authentication)
RFC 2113 (Router Alert)
RFC 2131/3396 (DHCP)
RFC 2132 (DHCP Options)
RFC 2138/2865 (RADIUS)
RFC 2139/2866 (RADIUS Accounting)
RFC 2236 (IGMP v2)
RFC 2267/2827 (IP Spoofing)
RFC 2328 (OSPF v2)
RFC 2338/3768 (VRRP)
RFC 2362 (PIM-SM)
RFC 2370/3630 (OSPF Opaque LSA option)
RFC 2373/3513/4291 (IPv6 addressing architecture)
RFC 2375 (IPv6 Multicast Addresses)
RFC 2385 (BGP – MD5)
RFC 2439 (BGP Route flap dampening)
RFC 2452 (IPv6 TCP MIB)
RFC 2454 (IPv6 UDP MIB)
RFC 2460 (IPv6 Specification)
RFC 2461 (IPv6 Neighbor discovery)
RFC 2462 (IPv6 Stateless Address Autoconfiguration)
RFC 2463 (ICMPv6)
RFC 2464 (IPv6 over Ethernet)
SPECIFICATIONS
(CONTINUED)