30" (762 mm) ELECTRIC RANGE INSTALLATION INSTRUCTIONS
(For 4 Wire, 60 Hz. Systems)
INSTALLATION AND SERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER.
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
P/N  316259203 REV C (1409)
Clearances and Dimensions
1.  Provide adequate clearances between the range and adjacent combustible surfaces.
2.  Location—Check location where the range will be installed. Check for proper electrical supply, and the stability 
of the floor.
3.  Dimensions that are shown must be used. Given dimensions provide minimum clearance. Contact surface must 
be solid and level.
*30" (762 mm) MINIMUM CLEARANCE BETWEEN THE TOP OF THE COOKING SURFACE AND THE  BOTTOM OF AN UNPROTECTED 
WOOD OR METAL CABINET; OR 24" (610 mm) MINIMUM WHEN BOTTOM OF WOOD OR METAL CABINET IS PROTECTED BY NOT 
LESS THAN 1/4" (6 mm) FLAME RETARDANT MILLBOARD COVERED WITH NOT LESS THAN NO. 28 MSG SHEET STEEL, 0.015" 
(0.4 mm) STAINLESS STEEL, 0.024" (0.6 mm) ALUMINUM OR 0.020" (0.5 mm) COPPER. 0" (0 mm) CLEARANCE IS THE MINIMUM FOR 
THE REAR OF THE RANGE. FOLLOW ALL DIMENSION REQUIREMENTS PROVIDED ABOVE TO PREVENT PROPERTY DAMAGE, 
POTENTIAL FIRE HAZARD, AND INCORRECT COUNTERTOP AND CABINET CUTS.
TO ELIMINATE THE RISK OF BURNS OR FIRE BY REACHING OVER HEATED SURFACE UNITS, CABINET STORAGE SPACE 
LOCATED ABOVE THE SURFACE UNITS SHOULD BE AVOIDED. IF CABINET STORAGE IS TO BE PROVIDED, THE RISK CAN 
BE REDUCED BY INSTALLING A RANGE HOOD THAT PROJECTS HORIZONTALLY A MINIMUM OF 5" (127 mm) BEYOND THE 
BOTTOM OF THE CABINETS.
English - Pages 1-4
Français - Pages 5-8
FRONT 
VIEW
Minimum to wall 
on either side of 
range above 
36’’ (914 mm) 
height.
SIDE
VIEW
1”
(25 mm)
36”
(914 mm)
30” 
(762 mm)
Minimum
30” 
(762 mm)
18”
(457 mm)
Minimum to 
cabinets on 
either side of 
range.
13”
330 mm
Maximum depth 
for cabinets 
above range top.
0” (0 mm) clearance below cooking top and at rear of range.
30”
(762 mm)
RANGE
OVERALL
DIMENSIONS
30”
(762 mm)
25- 3/4”
(654 mm)
48”
(1219 mm)
Maximum
49”
(1245 mm)
Maximum
Door Open
29- 7/8”
(759 mm)
36
 
1/8”
Centerline of 
range
All dimensions for electrical outlet location 
are maximum.
Dashed cubed area
 shows where the electrical outlet must be 
installed
 for flush to the wall installation.
25”
635 mm
11”
(279 mm)
22”
(559 mm)
Wall 
Edge
2-5/8” (67 mm) for models 
equipped with warmer drawers
3-1/2” (89 mm) for models 
equipped with storage drawers
6”
(152 mm) 
(3 mm)