Installation spacing for recessed area  
or closet installation
All dimensions show recommended and minimum spacing 
allowed. 
 
Additional spacing should be considered for ease of  
installation and servicing.
 
Additional clearances might be required for wall, door, floor 
moldings, and dryer venting.
 
Additional spacing should be considered on all sides of the 
dryer to reduce noise transfer.
 
For closet installation, with a door, minimum ventilation 
openings in the top and bottom of the door are required. 
Louvered doors with equivalent ventilation openings are 
acceptable.
 
Companion appliance spacing should also be considered.
Recommended installation clearances (dryer only):
ELECTRICAL REQUIREMENTS
It is your responsibility:
 
To contact a qualified electrical installer.
 
To be sure that the electrical connection is adequate and  
in conformance with the National Electrical Code, ANSI/ 
NFPA 70 - latest edition and all local codes and ordinances. 
 
The National Electrical Code requires a 4-wire power supply 
connection for homes built after 1996, dryer circuits involved  
in remodeling after 1996, and all mobile home installations. 
 
A copy of the above code standards can be obtained from: 
National Fire Protection Association, One Batterymarch Park, 
Quincy, MA 02269.
 
To supply the required 3 or 4 wire, single phase, 120/240 
volt, 60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 
volt electrical supply, if specified on the serial/rating plate) 
on a separate 30-amp circuit, fused on both sides of the line. 
Connect to an individual branch circuit. Do not have a fuse in 
the neutral or grounding circuit.
 
Do not use an extension cord.
 
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that  
the ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.
 
This dryer is manufactured ready to install with a 3-wire 
electrical supply connection. The neutral ground conductor  
is permanently connected to the neutral conductor (white wire) 
within the dryer. If the dryer is installed with a 4-wire electrical 
supply connection, the neutral ground conductor must be 
removed from the external ground connector (green screw), 
and secured under the neutral terminal (center or white wire) 
of the terminal block. When the neutral ground conductor is 
secured under the neutral terminal (center or white wire) of the 
terminal block, the dryer cabinet is isolated from the neutral 
conductor. The green ground wire of the 4-wire power cord 
must be secured to the dryer cabinet with the green  
ground screw.
 
If local codes do not permit the connection of a neutral  
ground wire to the neutral wire, see “Optional 3-wire 
connection” section.
 
A 4-wire power supply connection must be used when the 
appliance is installed in a location where grounding through  
the neutral conductor is prohibited. Grounding through the 
neutral is prohibited for (1) new branch-circuit installations after 
1996, (2) mobile homes, (3) recreational vehicles, and (4) areas  
where local codes prohibit grounding through the neutral 
conductors.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with  
clothes dryers. The kit should contain:
 
A UL listed 30-amp power supply cord, rated 120/240 volt 
minimum. The cord should be type SRD or SRDT and be  
at least 4 ft. (1.22 m) long. The wires that connect to  
the dryer must end in ring terminals or spade terminals  
with upturned ends.
 
A UL listed strain relief.
Mobile home - Additional installation requirements: 
This dryer is suitable for mobile home installations.  
The installation must conform to the Manufactured  
Home Construction and Safety Standard, Title 24 CFR, 
Part 3280 (formerly the Federal Standard for Mobile home 
construction and Safety, Title 24, HUD Part 280) or Standard 
CAN/CSA-Z240 MH.
Mobile home installations require: 
 
Metal exhaust system hardware, available for purchase from  
your dealer. For further information, see “Assistance or  
Service” section in your “Use and Care Guide.”
 
Special provisions must be made in mobile homes to 
introduce outside air into dryer. Openings (such as a nearby 
window) should be at least twice as large as dryer exhaust 
opening.
18" min.
(457 mm)
1"
(25 mm)
5"
(127 mm)
24 in.
min.
(155 cm
2
)
48 in.
min.
(310 cm
2
)
3"
(76 mm)
3"
(76 mm)
1"
(25 mm)
*
0" (0 mm) spacing is allowed.
*