12 
PROBLEMS WITH YOUR BEVERAGE CENTER? 
 
You can solve many common Beverage Center problems easily, saving you the cost of a possible 
service call. Try the suggestions below to see if you can solve the problem before calling the servicer. 
 
TROUBLESHOOTING GUIDE 
 
PROBLEM 
POSSIBLE CAUSE 
Beverage Center does not operate. 
Not plugged in. 
The appliance is turned off. 
The circuit breaker tripped or a blown fuse. 
Beverage Center is not cold enough. 
Check the temperature control setting. 
External environment may require a higher 
setting. 
The door is opened too often. 
The door is not closed completely. 
The door gasket does not seal properly. 
Turns on and off frequently. 
The room temperature is hotter than normal. 
A large amount of contents has been added to 
the Beverage Center. 
The door is opened too often. 
The door is not closed completely. 
The temperature control is not set correctly. 
The door gasket does not seal properly. 
The light does not work. 
Not plugged in. 
The circuit breaker tripped or a blown fuse. 
The light button is “OFF”. 
Vibrations. 
Check to assure that the Beverage Center is 
level. 
The Beverage Center seems to make too much 
noise. 
The rattling noise may come from the flow of the 
refrigerant, which is normal. 
As each cycle ends, you may hear gurgling 
sounds caused by the flow of refrigerant in your 
Beverage Center. 
Contraction and expansion of the inside walls 
may cause popping and crackling noises. 
The Beverage Center is not level. 
The door will not close properly. 
The Beverage Center is not level. 
The door was reversed and not properly installed. 
The gasket is dirty. 
The shelves are out of position.