WineMate Ducted Wine Cooling System - 1500 Cu. Ft. Uso Y Cuidado

Descargar
Página de 18
                                                                                
- 6 -
Installation Instruction 
 
 
 
1. Location 
 
•  WINEMATE ducted system is shipped ready for use 
•  Place the unit in a properly ventilated location. If it is not, heat exhausted 
by the condensing unit will build up and the cooling system will not operate 
properly.  
•  Leave minimum 3 feet clearance between the exhaust pipe and the wall. 
•  Leave minimum 1 foot clearance for the fresh air supply pipe. 
•  Air flow from the cold air discharge pipe should be unobstructed for at 
least 1 foot. 
•  Unit should be elevated to avoid possible flooding and shaded from direct 
sun. It should not be exposed to temperatures higher than 125 
°
F or lower 
than 20 
°
F.  
•  Overall combined duct length can be up to 50 ft long. 
 
2. Refrigeration Piping 
 
 
Model 
 
Drain Tube Diameter 
(inch) 
 
 
Air Pipe Diameter 
(inch) 
VINO4500DS 1/2 
VINO6500DS 1/2 
VINO8500DS 1/2 
 
3. Air Sensor 
 
The air sensor is recommended to place in the wine room. If it is in a return duct, 
the temperature differential may lead to erroneous readings.