WineMate Ducted Wine Cooling System - 1500 Cu. Ft. Uso Y Cuidado
- 6 -
Installation Instruction
1. Location
• WINEMATE ducted system is shipped ready for use
• Place the unit in a properly ventilated location. If it is not, heat exhausted
by the condensing unit will build up and the cooling system will not operate
properly.
properly.
• Leave minimum 3 feet clearance between the exhaust pipe and the wall.
• Leave minimum 1 foot clearance for the fresh air supply pipe.
• Air flow from the cold air discharge pipe should be unobstructed for at
least 1 foot.
• Unit should be elevated to avoid possible flooding and shaded from direct
sun. It should not be exposed to temperatures higher than 125
°
F or lower
than 20
°
F.
• Overall combined duct length can be up to 50 ft long.
2. Refrigeration Piping
Model
Drain Tube Diameter
(inch)
Air Pipe Diameter
(inch)
VINO4500DS 1/2
8
VINO6500DS 1/2
8
VINO8500DS 1/2
8
3. Air Sensor
The air sensor is recommended to place in the wine room. If it is in a return duct,
the temperature differential may lead to erroneous readings.