D9412GV3/D7412GV3 | Program Entry Guide | 4.0  Schedules (Skeds) 
EN | 116 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
Default: 
Selection: 
0 to 24, 28, 29 
 
 
 
  S## Area 1[through #] 
 
 
 
 
Yes 
Unbypass all 
points in Area #. 
Unbypass All Points: This function 
is not available as a keypad function. 
The entry in the S## Area # prompt 
defines the area(s) where the sked 
unbypasses all points. The sked 
unbypasses all points in the area, 
regardless of how they were 
bypassed. This sked can unbypass 
all points in multiple areas. 
Default: No 
Selection: Yes or No 
Select Yes to unbypass all 
points in the areas indicated. 
 
No 
Do not 
unbypass all 
points in  
Area #. 
 
 
 
  S## Relay Number 
 
 
 
 
Blank 
No relay is 
activated. 
Relay On: This function emulates 
the Change Relay keypad function to 
turn relays on. The entry in the S## 
Relay Number
 prompt defines the 
specific relay this sked activates. 
The sked can activate one relay. 
Default: Blank 
Selections: Blank,  
1 to 128 for D9412GV3, 
1 to 64 for D7412GV3 
Enter the number of the relay 
the sked activates 
1 to 128 
Relay to 
activate. 
 
 
 
  S## Relay Number 
 
 
 
 
Blank 
No relay is 
turned off. 
Relay Off: This function emulates 
the Change Relay? keypad function 
to turn relays off. The entry in the 
S## Relay Number prompt defines 
the relay this sked turns off. The 
sked can turn off only relays that are 
set by a sked. The sked can turn off 
one relay. 
Default: Blank 
Selections: Blank,  
1 to 128 for D9412GV3, 
1 to 64 for D7412GV3 
Enter the number of the relay 
that turns the sked off. 
1 to 128 
Relay to turn off. 
All Relays Off: This function is not available as a keypad function. This sked function turns off all 
relays that are turned on by a sked. This is a panel-wide function. 
No other parameters require input for this option. 
(Continued on next page.)