D9412GV3/D7412GV3 | Program Entry Guide | 2.0  Panel and Area Wide Parameters 
EN | 76 
 
 
Bosch Security Systems, Inc. | 10/11 | F01U170807-02 
 
L## Disarm Level 
Default: 
Refer to the program record sheet 
Selection: 
I, D, or - 
Users change the Master Armed 
state and Perimeter Armed state to 
Perimeter Instant. The armed state 
does not change in other areas, and 
the armed state does not change if 
the area is already in the perimeter 
instant or disarmed state. User 
needs access level for Master 
Armed (M) state. 
Users change the local area’s 
Master Armed state and Perimeter 
Armed state to the Disarm state. 
User needs access level for Master 
Armed (M) or Perimeter Armed (P) 
state. All areas within the scope of 
the keypad assigned to the D# CC# 
Scope
 in the access handler, and 
areas to which the user has disarm 
rights, disarm as programmed. 
Users do not have disarm rights in 
this area. 
 
 
 
Burglar bells are silenced in the local area 
when a user disarms with a token or card 
or presents the token or card during an 
alarm. The user must use a passcode to 
silence a Fire Bell. Cancel Reports are 
sent after a valid passcode or token or 
card silences the bell. 
 
 
Opening and Closing Reports are sent to 
the central station receiver if programmed. 
For more information on programming 
this prompt for a shared area, refer to 
Access Control Readers Assigned to the 
Shared Area
 in Section 2.8.2 Shared-
Area Characteristics
 on page 41. 
 
L## Function Level 
Default: 
Refer to the program record sheet 
Selection: 
M, D, C, or - 
Activate the custom function 
assigned to the door in this area 
while the area is Master Armed or 
Disarmed only. 
Activate the custom function 
assigned to the door in this area 
while the area is Disarmed only. 
User can activate the custom 
function assigned to the door in this 
area while the area is Master Armed, 
Perimeter Armed or Disarmed. 
User cannot activate the custom 
function assigned to the door in this 
area. 
 
 
When a token or card can also disarm an 
area, the custom function starts after the 
area disarms. 
 
 
A user does not require L## Security 
Level
 or L## Disarm Level authority to 
activate a custom function with a token or 
card. 
 
 
Tokens or cards that are used to execute 
Custom Functions must have a passcode 
assigned to the corresponding User###.