Cisco Systems OL-16447-01 Manual De Usuario

Descargar
Página de 102
 
3-6
Cisco ME 3400E Ethernet Access Switch Hardware Installation Guide
OL-16447-01
Chapter 3      Installing and Removing AC- and DC-Power-Supply Modules
Power-Supply Module Installation
Figure 3-5
Blank Cover Installed on the Power-Supply Slot
Installing an AC-Power-Supply Module
This procedure is for installing an AC-power-supply module in the PSU 1 power-supply slot. Repeat 
these steps to install a power-supply module in the PSU 2 power-supply slot.
Note
If you operate the switch with two power supplies, enter the power-supply dual global 
configuration command to configure the switch to send a message when one power supply is 
missing.
Each AC-power input is dedicated to one power-supply module (PSU 1 or PSU 2). One AC-power input 
does not power on both power-supply modules at the same time (
Figure 3-6
AC-Power-Supply Diagram
To install an AC-powered power-supply module, follow these steps:
Step 1
Verify that the power from the power source is off.
Step 2
Insert the new power-supply module in the power-supply slot, and gently push it into the slot 
(see 
). When correctly inserted, the power-supply module is flush with the switch rear panel. 
Figure 3-7
Inserting an AC-Power-Supply Module in a Switch
PSU OK
+24V -48V
DC
2
8
094
8
AC-1
AC-2
PSU-1
PSU-2
2
8
09
3
7
PSU OK
AC
PSU OK
AC
2
8
0
8
27