Cisco Systems OL-16447-01 Manual De Usuario
3-16
Cisco ME 3400E Ethernet Access Switch Hardware Installation Guide
OL-16447-01
Chapter 3 Installing and Removing AC- and DC-Power-Supply Modules
Power-Supply Module Installation
Step 12
Confirm that both the DCA LED and the PSU 1 LEDs are green. (If you can access the switch rear panel,
verify that the power-supply module PSU OK LED is green.) See
verify that the power-supply module PSU OK LED is green.) See
for a description
of the power-supply module LEDs. See
and
for the status
and DC-power-supply LED descriptions.
shows the front of the switch when DC-power-supply modules are installed. The DC A and
DC B LEDs are green when the respective feeds are active.
Figure 3-22
DC-Power Terminal Block With Two Feeds
Note
This illustration shows two sets of feeds installed. You can install one set of feeds, A or B.
See the
for information on how to configure the power
supply settings.
Removing the DC-Power-Supply Module
Step 1
Turn off power at the DC circuits. To ensure that power is removed from the DC circuits, locate the
circuit breakers for the DC circuits, switch the circuit breakers to the OFF position, and tape the
circuit-breaker switches in the OFF position.
circuit breakers for the DC circuits, switch the circuit breakers to the OFF position, and tape the
circuit-breaker switches in the OFF position.
Step 2
Use a number-2 Phillips screwdriver to remove the plastic safety cover from the power-supply terminal
blocks.
blocks.
Step 3
Use a number-1 Phillips screwdriver to remove the DC-input power wires from the power terminals.
Step 4
Use a Phillips screwdriver to loosen the two captive screws at the lower edge that secure the
power-supply module to the switch chassis.
power-supply module to the switch chassis.
Step 5
Remove the power-supply module from the power slot by pulling on the extraction handle.
Caution
To prevent overheating and to maintain proper air flow, either a power-supply module or a blank cover
must be installed in each power-supply module slot at all times.You can order the blank cover (part
number ME34X-PWR-BLANK=) from Cisco.
must be installed in each power-supply module slot at all times.You can order the blank cover (part
number ME34X-PWR-BLANK=) from Cisco.
280831