Appendix B      Connector and Cable Specifications
Cables and Adapters
Figure B-5
Alarm Input Port Pinouts
Cables and Adapters 
  •
  •
  •
SFP Module Cables 
Each port must match the wave-length specifications on the other end of the cable, and for reliable 
communications, the cable must not exceed the required cable length. Copper 1000BASE-T SFP 
transceivers use standard four twisted-pair, Category 5 (or greater) cable at lengths up to 328 feet (100 
meters). 
280950
2 3
1
4 5 6 7 8
Pin
Alarm connection
1
2
3
4
5
6
7
8
Alarm 1 input
Alarm 2 input
no connection
Alarm 3 input
Alarm 4 input
no connection
no connection
Alarm common
Table B-1
Fiber-Optic SFP Module Port Cabling Specifications 
SFP Module
Wavelength (nanometers)
Fiber Type
Core 
Size/Cladding 
Size (micron)
Modal 
Bandwidth 
(MHz/km)
1
Cable Distance
100BASE-BX 
(GLC-FE-100BX-D
 
GLC-FE-100BX-U)
1310 TX
 
1550 RX
SMF
G.652
2
32,810 feet (10 km) 
100BASE-EX
1310
SMF
G.652
2
131,240 ft (40 km)
100BASE-FX 
(GLC-GE-100FX)
1310
MMF
50/125
 
62.5/125
500
 
500
6,562 feet (2 km) 
 
6,562 feet (2 km)
100BASE-FX 
(GLC-FE-100FX)
1310
MMF
50/125
 
62.5/125
500
 
500
6,562 feet (2 km) 
 
6,562 feet (2 km)
100BASE-LX 
(100BASE-LX10)
1310
SMF
G.652
2
32,810 feet (10 km) 
100BASE-ZX
1550
SMF
G.652
262,480 ft (80 km)