Viewsonic PJ510 Manual De Usuario

Descargar
Página de 49
35
ViewSonic  PJ510
Troubleshooting
Related Messages
When the unit's power is ON, messages such as those shown below may be displayed. When any 
such message is displayed on the screen, please respond as described below. If the same message is 
displayed after the treatment, or if a message other than the following appears, please contact your 
dealer or service company.
Note:
* Although this message will be automatically disappeared after around 3 minutes, it will be 
reappeared every time the power is turned ON.
Message
Description
TO MAXIMIZE PERFORMANCE, 
LAMP REPLACEMENT IS RECOM-
MENDED.
The unit does not display a warning message on the screen when 
the lamp expires or fails. When the lamp does not light, this indi-
cates that the lamp is no longer functional and should be replaced. 
Replace the lamp and do not forget to reset the timer.
CLEAN THE AIR FILTER
AFTER CLEANING AIR FILTER,
RESET THE FILTER TIMER.
A note of precaution when cleaning the air filter.
After cleaning the filter, operate FILTER TIME of the OPTION Menu, 
then perform reset of the filter timer.
NO INPUT IS DETECTED
ON ***
There is no input signal.
Check the signal input connection and the status of the signal 
source.
SYNC IS OUT OF RANGE
ON ***
The horizontal or vertical frequencies of the inputted signal is out-
side of the operating range limits of this unit. Please confirm the 
specs for this unit or the signal source specs.
CHECK THE AIR FLOW
The internal temperature is rising. Please turn the power OFF, then 
allow the unit to cool down for approximately 20 minutes. After hav- 
ing confirmed the following items, then please reset the power to 
ON.
• Is there blockage of the air filter?
• Is the air filter dirty?
• Does the ambient temperature exceeds 35°C?
CLEAN THE AIR FILTER
POWER OFF FIRST,
THEN CLEAN THE AIR FILTER.
AFTER CLEANING THE AIR FIL-
TER, RESET THE FILTER TIMER.
A note of precaution when cleaning the air filter. 
Please immediately turn the power off, and clean or change the air 
filter by referring to the “Air Filter” section of this manual. After you 
have cleaned or changed the air filter, please be sure to reset the fil-
ter timer.
If the same message is displayed after the treatment, please clean 
the transparent area of filter cover and the dust-detecting window, 
according to the following.