B&B Electronics 232PE Manual De Usuario

Descargar
Página de 21
A-6
Appendix A
232PE3095 Manual
B&B Electronics  --  PO Box 1040  --  Ottawa, IL  61350
PH (815) 433-5100  --  FAX (815) 434-7094
Chart 9.  RS-422/485 4-Wire Device to Port (A - D)   Configured
as an RS-422 /485 Port.
Master port of 232XSS configured as an RS-232 DCE port.
RS-422/485
4-Wire
 Device
Signal
Direction
232PE
Ports A - D
DB25 Connector
TD (A)*
----------->
3 - RD (A)
TD (B)*
----------->
16 - RD (B)
Signal Ground
<---------->
7 - SG
RD (A)*
<-----------
2 - TD (A)
RD (B)*
<-----------
14 - TD (B)
* If the device being connected uses "+" and "-" in place of "B"
and "A", the "+" replaces the "B" and the "-" replaces the "A".
NOTE:  Make sure the port's set up jumpers are in the proper
position for four-wire communications.
Chart 10.  RS-422/485 2-Wire Device to Port (A - D) Configured
as an RS-422/485 Port.
Master port of 232XSS configured as an RS-232 DCE port.
RS-422/485
2-Wire
 Device
Signal
Direction
232PE
Ports A - D
DB25 Connector
Data (A)*
<---------->
2 - TD (A)
Data (B)*
<---------->
14 -TD (B)
Signal Ground
<---------->
7 - SG
* If the device being connected uses "+" and "-" in place of "B"
and "A", the "+" replaces the "B" and the "-" replaces the "A".
NOTE:  Make sure the port's set up jumpers are in the proper
position for two-wire communications.