Chapter 5      Troubleshooting the System Hardware
  Symptoms and Solutions
5-64
Cisco Wide Area Application Engine 7326 Hardware Installation Guide
OL-6831-02
System Shutdown
Use 
 for troubleshooting when experiencing system 
shutdown related to voltage or temperature problems.
Table 5-26
Voltage-Related System Shutdown
Error Message
Cause and Action
System shutoff due to x current over max value 
(level—critical; system drawing too much current 
on voltage x bus)
See the 
System shutoff due to xV overvoltage 
(level—critical; system shutoff due to x supply 
overvoltage)
1.
Check the power supply connectors.
2.
Check the power supply.
3.
Check the power cage assembly.
System shutoff due to x undervoltage 
(level—critical; system shutoff due to x supply 
undervoltage)
1.
Check the power supply connectors.
2.
Check the power supply.
3.
Check the power cage assembly.
System shutoff due to VRM x overvoltage
The VRM x needs to be replaced. Have the system 
serviced.
System shutoff due to excessive (< 240 VAC) 
loading
1.
See the 
2.
Cycle AC power on and off.