Installation Requirements
. Plumbing
 
Minimum maintained inlet pressure 70 kPa (0.7 bar).
 
00 kPa (.0 bar) recommended for satisfactory operation. 
 
Maximum static inlet pressure 1000 kPa (10 bar).
 
Minimum static pressure 0 kPa (0. bar) to keep the inlet valve closed.
  
. Electrical
 
The Mira Azora 9.8 kW requires a 45 Amp fuse.
 
The terminal block will accept cable up to 6 mm
 
.
3. Standards and Approvals
 
The Mira Azora complies with all relevant directives for CE marking.
. Plumbing
Specifications
 
The appliance is designed to operate with a minimum maintained inlet
 
pressure of 0.7 bar up to a maximum static inlet pressure of 10 bar.
 
When installed in very hard water areas (above 00 ppm temporary
 
hardness) your installer may advise the installation of a water treatment
 
device, to reduce the effects of limescale formation. Your local water
 
company will be able to advise the hardness of water in your area.
 
It is recommended that a non-restrictive (free flowing) isolating valve
 
is fitted in the cold water supply pipe to allow the complete maintenance
 
of the appliance. Do not use a valve with a loose washer plate (jumper)
 
as this can lead to a build up of static pressures.
 
The appliance is suitable for installation within the shower area. It is fitted
 
with a pressure relief device and must be positioned over a water
 
catchment area with the controls at a convenient height for all users.
 
The appliance must be fitted on to a finished flat and even wall surface
 
(this wall surface should be tiled or waterproofed).  
Do not
 fit the
 
appliance to the wall and tile up to the case.  For safety requirements, an
 
air gap must be left behind the appliance.