ICOM IC F121S Manual De Usuario

Descargar
Página de 74
5 - 6
*The output level of the standard signal generator (SSG) is indicated as the SSG’s open circuit.
SOFTWARE ADJUSTMENT – continued
Select an operation using [
↑] / [↓] keys, then set specified value using [←] / [→] keys on the connected computer keyboard.
Minimum distortion
level
Set  “SQL level” to
close squelch.
Then set “SQL level”
at the point where
the audio signals
just appears.
1
1
• Operating freq. : 136.000 MHz
• IF bandwidth
: Wide
• Connect a standard signal generator to
the antenna connector and set as:
Frequency
: 136.000 MHz
Level
: 10 µV* (–87 dBm)
Modulation
: 1 kHz
Deviation
: ±3.5 kHz
[N/W]
±2.8 kHz
[N/M]
• Receiving
• Operating freq. : 155.000 MHz
• IF bandwidth
: Narrow
• Connect an SSG to the antenna con-
nector and set as:
Frequency
: 155.000 MHz
Level
: 0.2 µV* (–121 dBm)
Modulation
: 1 kHz
Deviation
: ±1.75 kHz
• Receiving
RX
SENSITIVITY
[BPF T1], 
[BPF T2]
SQUELCH
LEVEL
[SQL]
MAIN
Rear
panel
Connect a SINAD meter with a
4
Ω load to the external [SP]
jack.
Connect a SINAD meter with a
4
Ω load to the external [SP]
jack.
ADJUSTMENT
ADJUSTMENT CONDITION
MEASUREMENT
VALUE
UNIT
LOCATION
CONVENIENT:
The BPF T1–BPF T2 can be adjusted automatically.
q-1: Set the cursol to “BPF ALL” on the adjustment program and then push [ENTER] key.
q-2: The connected PC tunes BPF T1, BPF T2 to peak levels.
or
w-1: Set the cursol to BPF T1 or BPF T2 as desired.
w-2: Push [ENTER] key to start tuning.
w-3: Repeat w-1 and w-2 to perform additional BPF tuning.