 B-VENT GAS FIREPLACES  •  MODELS SLBV-35, SLBV-40  •  INSTALLATION INSTRUCTIONS
Note: Installation and repair should be done 
by a qualified service person. The appliance 
should be inspected before use and at least 
annually by a professional service person. 
More frequent cleaning may be required due 
to  excessive  lint  from  carpeting,  bedding 
material, etcetera. It is imperative that control 
compartments,  burners  and  circulating  air 
passageways of the appliance be kept clean.
Remarque  :  L’installation  et  la  répara-
tion devrait être confiées à un technicien 
qualifié.  L’appareil  devrait  faire  l’objet 
d’une inspection par un technicien profes-
sionnel avant d’être utilisé et au moins 
une fois l’an par la suite. Des nettoyages 
plus fréquents peuvent être nécessaires si 
les tapis, la literie, et cetera produisent 
une  quantité  importante  de  pous-sière. 
Il  est  essentiel  que  les  compartiments 
abritant  les  commandes,  les  brûleurs 
et  les  conduits  de  circulation  d’air  de 
l’appareil soient tenus propres.
do  not  use  these  appliances  if  any  part 
has been under water.  Immediately call a 
qualified, professional service technician 
to  inspect  the  appliance  and  to  replace 
any  parts  of  the  control  system  and  any 
gas control which have been under water.
Ne pas utiliser cet appareil s’il a été 
plongé,  même  partiellement,  dans 
l’eau.  Appeler  un  technicien  qualifié 
pour inspecter l’appareil et remplacer 
toute partie du système de commande 
et toute commande qui a été plongée 
dans l’eau.
Only trim kit(s) supplied by the manufacturer 
shall be used in the installation of this ap-
pliance.
Seules les trousses de garniture fournies 
par le fabricant doivent être utilisées pour 
l’installation de cet appareil.
These appliances comply with National Safety 
Standards  and  are  tested  and  listed  by  ITS 
(Report No. 100017854) to ANSI Z21.50 (in 
Canada, CSA-2.22) and to CAN/CGA-2.17-M91 
in both USA and Canada (latest editions at time 
of manual publication) as vented gas fireplaces.
Both  millivolt  and  electronic  versions  of 
these  appliances are listed by ITS for instal-
lation in bedrooms in the United States (not 
approved in Canada). 
These appliances must not be connected to a 
chimney or flue serving a separate solid fuel 
burning appliance.
Installation must conform to local codes, or, in 
the absence of local codes, with the National 
Fuel Gas Code, ANSI Z223.1/NFPA 54 (latest 
edition), or the Natural Gas and Propane Instal-
lation Code, CAN/CSA B149.1 (latest edition). 
The appliance, when installed, must be electri-
cally grounded and wired in accordance with 
local codes or, in the absence of local codes, with 
the USA National Electrical Code, ANSI/NFPA 
70 (latest edition) or, in Canada, the Canadian 
Electrical Code, CSA C22.1 (latest edition).
Provide adequate clearances around air open-
ings and adequate accessibility clearance for 
service and proper operation. Never obstruct 
the front opening of the appliance.
These appliances are designed to operate on 
natural or propane gas only. The use of other 
fuels  or  combination  of  fuels  will  degrade 
the performance of this system and may be 
dangerous.
These fireplaces are designed as supplemental 
heaters;  therefore,  it  is  advisable  to  have  an 
alternate  primary  heat  source  when  installed 
in a dwelling.
MILLIVOLT MOdELS: The millivolt appliances 
are  manually  controlled  and  feature  a  spark 
igniter (piezo) that allows the appliance's pilot 
gas to be lit without the use of matches or bat-
teries. This system provides continued service 
in the event of a power outage.
ELECTRONIC MOdELS: The electronic appli-
ances are manually controlled and feature an 
electronic  intermittent  pilot  ignition  system.  
External electrical power is required to operate 
these units.
ALL  MOdELS:  Both  millivolt  and  electronic 
models  come  standard  with  a  manually-
modulated  gas  valve;  flame  appearance  and 
heat output can be controlled at the gas valve. 
BTU  input  rates  for  all  models  are  listed  in 
Table 1, below.
 Input (BTU/hr) Manually-Modulated 
Gas Valves (all models)
Models
Input Rate (BTU / HR)
Nat. Gas
Prop. Gas
SLBV-35
 
17,000 high
13,000 low
17,000 high
14,000 low
SLBV-40
22,000 high
17,000 low
20,000 high
15,500 low
Table 1
       WARNING 
Improper installation, adjust-
ment, alteration, service or 
maintenance can cause injury 
or property damage. Refer to 
this manual. For assistance or 
additional information consult 
a qualified installer, service 
agency or the gas supplier.
       WARNING 
Failure to comply with these 
installation instructions will 
result in an improperly installed 
and operating appliance, void-
ing its warranty. Any change to 
this appliance and/or its operat-
ing controls is dangerous.
       WARNING 
Clothing or other flammable 
material should not be placed 
on or near the appliance.
       AVERTISSEMENT 
On  ne  devrait  pas  placer  de 
vêtements  ni  d’autres  matières 
inflammables sur l’appareil ni à 
proximité.
       WARNING 
Any  safety  screen  or  guard 
removed for servicing the appli-
ance must be replaced prior to 
operating the appliance.
       AVERTISSEMENT 
Tout écran ou protecteur retiré 
pour  permettre  l’entretien  de 
l’appareil  doit  être  remis  en 
place avant de mettre l’appareil 
en marche.
       WARNING 
Improper installation or use  
of this appliance can cause 
serious injury or death from 
fire, burns, explosion or 
carbon monoxide poisoning.
 
GENERAL INfORMATION 
(continued)