1.  Pick a location on a wall with a clear space in the room. In 
selecting a location for installation, it is necessary to provide 
adequate  accessibility  clearances  for  servicing  and  proper 
installation. Be sure to locate the unit close enough to a 110 
VAC wall receptacle to properly power appliance.
2.  When facing the front of the furnace the minimum clearances 
from casing to combustible construction are 0” (0mm) on top, 
0” (0mm) on each side, recommend 4” (102mm) on sides for 
servicing and 0”(0mm) from the floor and 0” (0mm) to rear 
wall.
3.  The minimum distance from the center of the vent cap to the 
nearest outside corner or obstruction is 12” (305mm).
4.  The minimum wall depth is 4” (102mm) and the maximum is 
48” (121.92cm). 
The  vent  terminal  of  a  direct  vent  appliance,  with  an  input  of 
50,000 BTU (14.6KW) per hour or less shall be located at least 9” 
(229mm) from any opening through which flue gases could enter 
a building.
The bottom of the exhaust vent terminal and the air intake shall 
be located at least 12” (305mm) above grade and must be vented 
outside.
WARNING: The nearest point of the vent cap should be 
a minimum horizontal distant of six (6) feet (1.83m) from 
any pressure regulator. In case of regulator malfunction, 
the six (6) feet (1.83m) distance will reduce the chance of 
gas entering the vent cap.
Installation on Rugs and Tile
If this appliance is to be installed directly on carpeting, tile, or other 
combustible material, other than wood flooring, the appliance shall 
be installed on a metal or wood panel extending the full width and 
depth of the appliance.
The base referred to above does not mean the fire-proof base as 
used on wood stoves. The protection is primarily for rugs that may 
be extremely thick and light-color tile that can discolor.
Locating Wall Opening 
The recommended location for this furnace is on an outside wall. 
Locate wall studs so that wall vent opening will be located between 
wall studs. The wall opening required for venting is a 3 1/2” (89mm) 
minimum diameter opening.
Refer to Figures 3 and 6 for positioning the heater on wall and for 
locating gas line connection and vent opening. Furnace can sit on 
the floor.
CLEARANCES FOR DIRECT VENT
HEATER INSTALLATION FOR DIRECT VENT
1 9/16”
4 3/32”
Figure 2