ENVIRONMENTAL REQUIREMENTS
Operating Temperature:
+5
°
 to +40
°
C (41
°
 to 104
°
F)
Non-operating Temperature:
-30
°
 to +80
°
C (-22
°
 to 176
°
F)
Operating Humidity:
5% to 95% (non-condensing)
Table A-2
Fiber Optic Interface (All Ports)
Parameter
Typical
Minimum
Maximum
Transmitter 
Peak Wave 
Length
1310 nm
1265 nm
1380 nm
Spectral Width
95 nm
   
125 nm
Rise Time
3.0 ns
2.7 ns
5.0 ns
Fall Time
2.5 ns
2.2 ns
5.0 ns
Duty Cycle
50.1%
49.6%
50.7%
Bit Error Rate
 Better than 10
-10