Cleveland Range 22CET3A Manual De Usuario

Descargar
Página de 46
20
1. Locating the Steamer
Location and Clearance Requirements of the Steamer
(1) Do not locate the steamer directly over a floor drain.
(2) Observe the following criteria when selecting an operating location for the SteamChef¥  3
steamer.
x
Maintain a 3-inch operating clearance at the sides of the unit, and at least a 4-inch
clearance at the back. 
x
A 12 in clearance is recommended on the right side for servicing the steamer.
x
Approximately 24 inches of clearance is recommended in front of the unit for opening the
door and standard pan clearance.
Figure 4-1 SteamChef
¥
 3 Dimensions and Clearances
Electrical
6-kW Units
1-PH
3-PH
VOLTS
WATTS
AMPS
AMPS
208
6400
30.8
17.8
220
5440
25
14.3
240
6400
26.7
15.4
9-kW Units
1-PH
3-PH
VOLTS
WATTS
AMPS
AMPS
208
9400
45.2
26.1
220
7960
36.1
20.9
240
9400
39.2
22.6
Clearances
Right – 12.00”
Left – 3.00”
Rear – 4.00”
21.640
17.434
33.826
18.500
22.500
31.750
 3.000
12.000
24.000
30.167
 4.000
C1 Feed Water Reservoir
C2 Condenser Water