Step 1.  Turn control box power switch OFF and unplug the transformer or disconnect the solar panel.  Remove
 
 control box cover and disconnect battery lead wires from the battery terminals before wiring the lock
 
 board to the opener control board.
Step 2.   Connect the WHITE wire (included) to Terminal #1 on the lock board.  Connect the RED battery lead
 
 wire (included) to Terminal #5 on the lock board.  
Step 3.  Attach the RED control board battery lead wire to one spade tongue on a double spade tongue connector 
(included).  Attach the BLACK control board battery lead wire to one spade tongue on the other double 
spade tongue connector (included).
Step 4.  Pull RED and BLACK wires from gate lock through the strain relief and into the control box.  Attach 
BLACK wire to Terminal #3 on lock board. Attach RED wire to Terminal #4 on lock board (see Lock 
Board Wiring Chart below
). 
Step 5.  Attach RED lock board battery lead wire to the double spade tongue terminal with the RED control 
board lead wire.  Attach the BLACK lock board battery lead wire to the double spade tongue connector 
with the BLACK control board Lead Wire.
Step 6.  Connect the WHITE wire from the lock board directly to the FIRST OPERATOR terminal block along 
with the power cable wire from the opener arm.  Connect the WHITE wire to the BLACK terminal for 
a Pull-to-Open installation or connect WHITE wire to the RED terminal for a Push-to-Open installation  
(see illustration on page 11).
Step 7.  Reconnect opener to gate bracket. Connect the BLACK Battery lead wire (included) to Terminal #2 on 
the lock board. (See Lock Board Wiring Chart below). Connect RED wires (with double spade tongue 
terminal) to POSITIVE (+) battery terminal and the BLACK wires (with double spade tongue terminal) 
to the NEGATIVE (–) battery terminal.  Plug the transformer in or rewire the solar and turn the control 
box power switch ON. Test opener and lock to make sure it functions properly and make adjustments if 
necessary.
Wiring the Lock to Gate Opener Control Boards
FM700, PRO SW-1000, PRO-SW2000, PRO-SL1000, PRO-SL2000
RED Wire To Battery
Positive (+) Terminal
RED Wire From Lock 
BLACK Wire From Lock
WHITE Wire to
BLACK on OperatorTerminal
Lock Board
BLACK Wire To Battery 
Negative (–) Terminal
1 2 3 4 5
Time 
A
d
j
* Place a dab of petroleum 
jelly on the terminal con-
tacts to prevent corrosion.
Lock  Board 
Wiring Chart
NOTE: It is recommended that the time adjustment knob is turned all the way to the right.