FSAF24-BAL(-S) US
Spring Return, 24 V, 3-Position, 100% Open Override
Operation at 250°F for limited time per UL555S testing
Accessories (AF series accessories may be employed)
IND-AF2
Damper position indicator
K4-1 US
Universal clamp for up to 1.05” dia. jackshafts
KH-AF
Crank arm for up to 3/4” round shaft (Series 2)
KH-AF-1
Crank arm for up to 1.05” jackshaft (Series 2)
KH-AFV
V-bolt kit for KH-AF and KH-AF-1
Tool-01
10 mm wrench
ZDB-AF2
Angle of rotation limiter
ZG-100
Universal mounting bracket
ZG-101
Universal mounting bracket
ZG-103 
Universal mounting bracket
ZG-104
Universal mounting bracket
ZG-106
Mounting bracket for Honeywell
®
 Mod IV replacement or new
crank arm type installations
ZG-107
Mounting bracket for Honeywell
®
 Mod III or Johnson
®
 Series
100 replacement or new crank arm type installations
ZG-108
Mounting bracket for Barber Colman
®
MA 3../4.., Honeywell
®
Mod III or IV or Johnson
®
 Series 100 replacement or new 
crank arm type installations
ZG-AF
Crank arm adaptor kit for AF/NF 
ZG-AF108
Crank arm adaptor kit for AF/NF 
ZS-100 
Weather shield (metal)
ZS-150
Weather shield (polycarbonate)
ZS-300
NEMA 4X housing
22965-00001
12 mm form fit square shaft adaptor 
For an overview of how to apply the accessories, see Belimo Mechanical Accessories and refer to the Belimo
Mounting Methods Guide.
NOTE:  When using FSAF24-BAL(-S) US actuators, only use accessories listed on this page. 
Typical Specification
Where indicated on drawings, combination fi re and smoke and balancing dampers 
shall be controlled by Belimo FSAF24-BAL or equal actuators. The actuators must 
be designed so that they may be used for either clockwise or counter clockwise 
failsafe operation. Actuator shall open damper in <75 seconds per UL555S and shall 
spring closed in under 20 seconds. Actuators shall have a 5-year warranty and be 
manufactured under ISO9001 International Quality Control Standards. 
Actuator shall have an adjustable Maximum Opening Potentiometer which shall be
used by the TAB contractor to adjust fl ow to that portion of the system fed by the
damper.
The actuator shall spring closed if either the smoke detector or alarm system
removes power from it. Actuator shall spring closed if the primary temperature
thermodisc opens due to high ambient of >165°F or as otherwise indicted on
drawings.
The actuator shall drive full open if either the smoke control system 100% open
override or Fire Fighters Smoke Control Station override is activated. Damper shall
spring closed again if the thermodisc of a combination fi re and smoke damper opens
due to high temperature (typically 250°F).
Wiring Diagrams
1
Provide overload protection and disconnect as required.
2
CAUTION Equipment Damage!
Actuators may be connected in parallel.
Power consumption and input impedance must be observed. 
3
Actuator may also be powered by 24 VDC.
4
Only connect Hot, Wire 2 to Wire 3 override control
5
For end position, interlock control, fan start-up, etc., FSAF24-BAL-S 
incorporates two built-in auxiliary switches: 2 x SPDT, 7A resistive, 2.5A 
inductive 120/250 VAC, UL listed, one switch is fi xed at 10°, one adjustable 
30° to 90°
6
For end position indication, interlock control, fan startup, etc.,
FSAF24-SR-S US incorporates two built-in auxiliary switches:
2 x SPDT, 7A resistive, 2.5A inductive 120/250 VAC, UL Approved, one
switch is fi xed at 10°, one is adjustable 30° to 90°.
6
Meets UL requirements without the need of an electrical ground
connection.
7
   Double insulated
WARNING Live Electrical Components!
G
  During installation, testing, servicing and troubleshooting of this product, it may be
necessary to work with live electrical components.  Have a qualifi ed licensed electrician or other 
individual who has been properly trained in handling live electrical components perform these
 tasks. Failure to follow all electrical safety precautions when exposed to live electrical compo-
nents could result in death or serious injury.
1
24 VAC Transformer
Line
Volts
4
OVERRIDE CONTROL
See Wiring Diagrams
on following pages for
typical methods.
3
1 Blk Com
2 Red Hot
3 Override Open
FSAF24-BAL US
2
6
7
0793-00001_p
g
2
Override control
S1
S2
S3
S4
S5
S6
5
2
NC
NO
NC
NO
10°
30° to 90°
FSAF24-BAL-S US
7
70793-00001_p
g
2
Auxiliary switch
 M40024 - 05
/10 - 
S
ubject to change.
 ©
 Belimo 
Aircontrols (U
S
A),
 Inc.