13 
3.4 Adjustments for 
   Technicians 
1) Magnetron heater voltage 
Magnetron heater voltage is formed at the MD 
Board of the antenna unit and preadjusted at 
the factory for use with any length of signal 
cable. Therefore no adjustment is required. 
However, verify heater voltage as follows: 
CAUTION
Lift the radome cover slowly.
The antenna radiator may be caught by 
the screw holes in the radome cover.
If you feel the radiator is caught by the 
screw holes, lower the cover, turn it a 
few degree and then lift it again.
Screw holes
(4 places)
 
Note: Turn the power on when measuring 
magnetron heater voltage. 
1.  Dismount the shield plate.   
MD board under
the shield plate
 
Figure 27 MD board 
2.  Turn on the power. Do not transmit the 
radar. 
3.  Connect a multimeter, set to 10 V DC 
range, between #6(+) and #4(-) of test 
point TP804 on the MD Board in the 
antenna unit. 
4.  Confirm that the multimeter shows 8.0 V 
±0.1 V. If it does not, adjust potentiometer 
VR801 on the MD Board. 
TP804
VR851
VR801
 