Furuno 1742 Manual De Usuario

Descargar
Página de 260
1. OPERATIONAL OVERVIEW 
 
1-7
1.3 
Turning the Unit On/Off 
Press the [POWER/BRILL] key to turn the unit on. A beep sounds and the 
equipment proceeds in the sequence shown below, displaying the product 
information screen, startup test results and the chart usage disclaimer, in that 
order. The startup test checks the ROM, RAM, internal battery and backup data 
for proper operation, displaying the results for each as OK or NG (No Good). If 
NG appears, an appropriate message appears on the screen. For any NG, try to 
press any key to go to the chart disclaimer screen, then perform the diagnostic 
test referring to the paragraph “7.5 Diagnostics.” 
RADAR PLOTTER
     STATION NAME:
        RADAR
FURUNO ELECTRIC CO., LTD.
CHARTS AVAILABLE
FLYBRDG = ANB01004
RADAR     = ANB01003
                 STARTUP TEST
ROM
OK
RAM
OK
BACKUP DATA
OK
INTERNAL BATTERY
OK
NO NATIONAL HYDROGRAPHIC
OFFICE HAS VERIFIED THE
INFORMATION IN THIS
COASTLINE DATA CARD AND NONE
ACCEPT LIABILITY FOR THE 
ACCURACY OF REPRODUCTION OR
ANY MODIFICATIONS MADE 
THEREAFTER. THIS PRODUCT WITH
THIS COASTLINE DATA CARD
DOES NOT REPLACE THE 
REQUIREMENT TO USE THE
APPROPRIATE PRODUCTS FOR
NAVIGATION ACCORDING TO
NATIONAL AND INTERNATIONAL
REGULATIONS.
è
è
Product information                            Startup test                                Chart disclaimer
PROGRAM No. 03591730**
Host Name
Chart List
** = Program version no. 
(Two program version numbers. 
One for NAVIO and one for C-MAP.)
 
The magnetron in the antenna unit takes about one minutes and thirty seconds 
to warm up before the radar can be operated. The time remaining for warm up of 
the magnetron appears at the center of the display, counting down from 1:30 to 
0:01. 
You may press any key at the chart disclaimer screen to show the last-used 
display, or wait several seconds to let the equipment do it for you. 
 
To turn the unit off, press and hold down the [POWER/BRILL] key until the 
screen goes dark (approx. 3 sec.). To protect the LCD attach the hard cover. 
Note that the network sounder will be turned off approx. three minutes after 
turning off the power. 
 
Note:
 You are asked if you want to start the simulation mode, which provides 
simulated operation of the equipment, the first time you turn on the power 
(or any time power is applied after a memory reset) the message shown 
below is displayed. Push the [ENTER] knob to start the simulation mode, 
or press the [CLEAR] key to start normal operation. For further details 
about the simulation mode, see the paragraph “1.9 Simulation Display.” 
           
START
SIMULATION MODE?
YES  ... PUSH ENTER KNOB
NO    ... PUSH CLEAR KEY
             TO SKIP.