Furuno 1622 Manual De Usuario

Descargar
Página de 24
 
 
11
Correct
Target pushed
inward
Target pushed
outward
 
Figure 23 Examples of improper and 
correct sweep timings 
1.  Transmit the radar on a range between 
0.125 and 0.5 nm and adjust the sensitivity 
and STC. 
2.  Visually select a straight echo (harbor wall, 
straight pier). 
3.  Select ADJ TMG on the menu. 
 
SEL MENU
BY 
/
 KEY
TOTAL ON TIME
     00000 : 00
TOTAL TX TIME
     00000 : 00
1. ADJ HDG
2. ADJ TMG
3. NM/KM
TUNE
IDENTIFY STRAIGHT TARGET
SUCH AS BREAKWATER. MAKE
ITS ECHO STRAIGHT ON SCREEN
BY USING 
t
/
u
 KEYS.
 
Figure 24 Installation menu, ADJ TMG selected 
4.  While looking at the target selected at step 
2, straighten it by pressing 
!
 if it is pulled 
inward, or 
"
 if it is pushed outward. 
4) Unit of range measurement for 
VRM and cursor 
The unit of range measurement for the VRM 
and the cursor may be selected to nautical mile 
or kilometers as follows: 
1.  Select NM/KM on the menu. 
 
SEL MENU
BY 
/
 KEY
TOTAL ON TIME
     00000 : 00
TOTAL TX TIME
     00000 : 00
1. ADJ HDG
2. ADJ TMG
3. NM/KM
TUNE
                 (RANGE UNIT)
PRESS  
t
/
u
 KEYS TO SELECT
NAUTICAL MILE OR KILOMETER
AS THE UNIT OF RANGE.
 
Figure 25 Installation menu, NM/KM selected   
2.  Select unit of range desired. 
3.  Press the [MENU] key to close the 
installation menu. 
3.4 Adjustments for   
   Technicians 
1) Magnetron heater voltage 
Magnetron heater voltage is formed at the MD 
Board of the antenna unit and preadjusted at 
the factory for use with any length of signal 
cable. Therefore no adjustment is required. 
However, verify heater voltage as follows: 
Note: Turn the power on when measuring 
magnetron heater voltage. 
1.  Dismount the shield plate.   
MD board under
the shield plate
 
Figure 26 MD board