Graco 311593N Manual De Usuario

Descargar
Página de 20
Models
311593N
3
Models
E-Flo 4-Ball Piston Pumps
Check your pump’s identification plate (ID) for the 6-digit part number of your 
pump. Use the following matrix to define the construction of your pump, based 
on the six digits. For example, Pump Part No. E P 2 1 6 0 represents electric 
power (E), pump (P), 230/460V motor (2), sensor circuit installed (1), 2000 cc 
MaxLife lower (6), and no stand installed (0). To order replacement parts, see 
the Repair-Parts manual 311594. 
Maximum Working Pressure and Pump Operational Limits
E-Flo 1500: 425 psi (2.93 MPa, 29.3 bar) Maximum Working Pressure
E-Flo 2000: 460 psi (3.22 MPa, 32.2 bar) Maximum Working Pressure
E-Flo 3000: 330 psi (2.31 MPa, 23.1 bar) Maximum Working Pressure
E-Flo 4000: 250 psi (1.75 MPa, 17.5 bar) Maximum Working Pressure
See Technical Data, page 18, for pressure and flow limits.
ID
ti8912a
E
P
2
1
6
0
First Digit
Second Digit
Third Digit
Fourth Digit
Fifth Digit
Sixth Digit
Power 
Source
Equipment 
Style
Motor
Sensor Circuit
Lower Size
Stand Option
E (electric) P (pump)
0
No motor
0
No circuit 
installed
1
1000 cc Chrome
0
No stand 
installed
1
230/400V, 5 HP, 
ATEX
1
Circuit installed
2
1500 cc Chrome
1
Stand 
installed
2
230/460V, 5 HP, 
UL/CSA
3
2000 cc Chrome
3
230/400V, 3 HP, 
ATEX
4
1000 cc MaxLife
®
4
230/460V, 3 HP, 
UL/CSA
5
1500 cc MaxLife
6
2000 cc MaxLife
7
750 cc Chrome
8
750 cc MaxLife