3. PLOTTER OPERATION 
 
3-60 
Alarm messages 
The table below shows the plotter alarm messages and their meanings 
Plotter alarm messages and their meanings 
Message Meaning 
ARRIVED AT XXX WAYPOINT! 
(XXX = waypoint number) 
Arrival alarm violated. 
ENTERED INTO AVOIDANCE 
AREA! 
Proximity alarm violated. 
EXCEEDED ANCHOR WATCH 
LIMIT! 
Anchor watch alarm violated. 
EXCEEDED XTE LIMIT! 
XTE alarm violated. 
SPEED ALARM!   
Speed alarm violated. 
TEMPERATURE ALARM! 
Water temperature alarm 
violated. 
TRIP ALARM! MILEAGE 
EXCEEDED 
Trip alarm violated. 
 
 
3.12  Resetting Trip Distance 
Trip distance is shown on the navigation data display. You can reset the trip 
distance to zero as follows: 
 
1.  Press the [MENU] key. 
2.  Press the SYSTEM CONFIGURATION and GENERAL SETUP soft keys in 
that order to show the GENERAL SETUP menu. 
KEY BEEP
ON
LANGUAGE
ENGLISH
RANGE UNIT
nm, kt
TEMPERATURE UNIT
F
DEPTH UNIT
ft
TEMPERATURE SOURCE 
NMEA
DEPTH SOURCE
NMEA
RESET TRIP LOG
NO
GENERAL
  SETUP1
EDIT
NEXT
      PAGE
RETURN
 
General setup menu, page 1 
3.  Use the cursor pad to select RESET TRIP LOG and press the EDIT soft key. 
4.  Use the cursor pad to select YES. 
5.  Press the ENTER soft key. 