3-11
3.4 
Checking Magnetron Heater Voltage 
Note: This confirmation/adjustment should only be performed by a qualified service 
technician. 
 
Magnetron heater voltage is formed on the PTU (1833C-BB)/MD (1823C-BB/1933C-BB/ 
1943C-BB/1953C-BB) Board of the antenna unit, and preadjusted at the factory. Therefore 
no adjustment is required. However, check magnetron heater voltage for confirmation as 
follows: 
 
1.  Open the antenna unit. 
2.  Turn on the power. Do not transmit the radar. 
3.  Connect a multimeter, set to 10 VDC range, on the MD (1823C-BB), PTU (1833C-BB) or 
RTB (1933C-BB/1943C-BB/1953C-BB) Board in the antenna unit, referring to the table 
below. 
4.  Confirm that the multimeter indication is as shown in the table below. 
 
 
MODEL1823C-BB MODEL1833C-BB 
MODEL1933C-BB/ 
1943C-BB/1953C-BB 
Check point 
TP804#6 (+) and #4 (-) 
on MD Board 
TP802#4 (+) and #6 (-) on 
PTU Board 
J825#4 and #6 (GND) on 
RTB Board 
Multimeter indication 
7.9 to 8.1 V 
7.4 to 7.6 V 
7.4 to 7.6 V 
Adjustment point 
VR801 on MD Board 
R106 on PTU Board 
VR801 on MD Board 
 
 
3.5 
Navigation Data Source   
The NAV SOURCE SETTINGS menu mainly selects the source of nav data. For navigator 
other than the FURUNO GP-310B/320B, speed averaging and local time offset (to use local 
time instead of UTC time) are also available from this menu. 
 
1.  Press the [MENU] key followed by E: SYSTEM CONFIGURATION, B: NAV OPTION 
and A: NAV SOURCE SETTINGS soft keys to show the NAV SETUP menu. 
NAV
SETUP
POSITION SOURCE
ALL
SPEED AVERAGING* 
0060second (s)
LOCAL TIME OFFSET*
+00:00
TEMP CALIBRATION
+00  F
DEPTH CALIBRATION
+00ft
* For GPS receiver other than GP-310B/320B.
E RETURN
A  EDIT
 
Nav setup menu