Motor brake and stop operation
4
4.14.2 Selection of regenerative brake and DC feeding (Pr. 30, Pr. 70)
*1
Used in combination with GZG, GRZG, or FR-BR.
*2
Used in combination with MT-BR5
<55K or lower>
When making frequent starts/stops, use the optional high-duty brake resistor (FR-ABR), brake unit (FR-BU2,
BU, FR-BU, MT-BU5) to increase the regenerative brake duty.
Use a power regeneration common converter (FR-CV) or power regeneration converter (MT-RC) for continuous
operation in regenerative status. 
Use a high power factor converter (FR-HC, MT-HC) to reduce harmonics, improve the power factor, or
continuously use the regenerative mode.
You can select either DC feeding mode 1 in which operation is performed with DC power (terminal P/+, N/-) or
DC feeding mode 2 in which operation is performed normally with the AC power (terminal R/L1, S/L2, T/L3) and
performed with DC power such as battery at occurrence of power failure.
Parameter 
Number
Name
Initial 
Value
Setting Range
Description
30
Regenerative function 
selection
0
Regeneration unit
Terminal for power 
supply to the inverter
0
Built-in brake resistor, inverter 
without regenerative function, 
brake unit (FR-BU
FR-BU, 
BU type) 
R/L1, S/L2, T/L3
10
P/+, N/-
(DC feeding mode 1)
20
R/L1, S/L2, T/L3 - P/+, N/-
(DC feeding mode 2)
1
High-duty brake resistor, brake 
unit (FR-BU2 
*2, 
MT-BU5), 
power regeneration converter 
(MT-RC)
R/L1, S/L2, T/L3
11
P/+, N/-
(DC feeding mode 1)
21
R/L1, S/L2, T/L3 - P/+, N/-
(DC feeding mode 2)
2
High power factor converter 
(FR-HC, MT-HC), power 
regeneration common 
converter (FR-CV)
P/+, N/-
70
Special regenerative 
brake duty
0%
55K or 
lower
0 to 30%
Set the %ED of the built-in brake transistor operation.
75K or 
higher
0 to 10%
Regeneration Unit
Power Supply to 
the Inverter
Pr. 30 
Setting
Pr. 70 
Setting
Remarks
Built-in brake (7.5K or lower), 
brake unit (FR-BU2 
FR-BU, BU)
R/L1, S/L2, T/L3
0
(initial value)
The regenerative brake duty is as follows.
⋅ FR-A720-0.4K to 3.7K  . . . . .  3%
⋅ FR-A720-5.5K, 7.5K . . . . . . .  2%
⋅ FR-A740-0.4K to 7.5K  . . . . .  2%
⋅ Other than the above . . . . . .  0%
(without built-in brake resistor)
P/+, N/-
10
R/L1, S/L2, T/L3 - 
P/+, N/-
20
High-duty brake resistor (FR-ABR)
(22K or lower)
R/L1, S/L2, T/L3
1
10/6%
Change the setting according to the 
capacity.
(7.5K or lower / 11K or higher)
P/+, N/-
11
R/L1, S/L2, T/L3 - 
P/+, N/-
21
High power factor converter (FR-HC),
power regeneration common 
converter (FR-CV)
P/+, N/-
2
0
(initial value)