7.  INITIAL SETTINGS
7-42
7.14
Fish Hunter Option Menu
You can set the parameters for the FishHunter
TM
 turns on the [Fish Hunter Option] 
menu. To open the [Fish Hunter Option] menu, select [Fish Hunter Option] from the 
[Installation Menu] window.
Note: The [Fish Hunter Option] menu is not shown with a sailboat and Fantum Feed-
back
TM
.
Circle
Rate of Turn:           
3
 
°
/s
Orbit
Radius:       
0.05
 
NM
SPIRAL
Speed:      
0.5
  
kn
            
Radius:     0.05 NM
Figure 8
Radius:       
0.05
 
NM
Square Turn
Side Length:        
1.0
 
NM
            
Azimuth: Auto
Zigzag
Turn Angle:    
90 
°
            
Termination: Continuous
Distance:
Number of Turns:
Width: 0.5 NM
Distance
Continuous
Number of Turns
Manual
Auto
Fish Hunter Option      
Circle
Orbit
Spiral
Figure 8
Square Turn
Zigzag
< Setting range >
Setting range depends on units 
set on the [Unit Setup] menu.
1°-30°/s
0.05-9.99 NM
[Speed]: 0.1-2.0 kn
[Radius]: 0.05-9.99 NM
0.05-9.99 NM
[Turn Angle]: 30°-150°
[Number of Turns]: 1-20
([Termination] = [Number of Turns])
[Distance]: 1-99 NM
([Termination] = [Distance])
[Width]: 0.1-9.9 NM
[Side Length]: 1.0-9.9 NM 
[Azimuth]: 0-359° ([Manual])