5.  MAINTENANCE, TROUBLESHOOTING
5-14
1201
Communication error
No communication between processor 
unit and control unit. Turn off power.
1203
FU remote controller error
Check remote controller.
1301
Missing heading data
Check heading sensor.
1303
Heading data is shifted.
Heading data has changed abruptly. 
Check heading sensor.
1305
No speed data. Please check 
speed source or enter manual 
speed value in Parameter Setup.
Check the speed source or enter the 
speed manually.
1307
No wind data
Check wind sensor.
1309
Wind data is shifted.
Wind data has changed abruptly. Check 
wind sensor.
1311
No NAV data. Wait for 1 sec-
onds.
Check nav data sensor.
1315
Degradation of NAV data quality. Check nav data sensor.
1317
No position data
Check position-fixing equipment.
1801
EVC Interface error
Communication error between the pro-
cessor unit and IPS interface unit. Check 
the connection between the processor 
unit and IPS interface unit.
1803
No contact with EVC.
Communication error between the VOL-
VO IPS gateway and IPS interface unit. 
Check the connection between VOLVO 
IPS gateway and IPS interface unit. Also 
check the connection between the VOL-
VO IPS gateway and EVC system.
1901
Rate sensor error
Check rate sensor.
1903
Backup error
All user and engineer default settings are 
restored. Reenter installation settings.
Fail
0001
Drive unit error. Please turn OFF 
and check drive circuit.
Turn off power
0003
Drive unit overloaded. Please 
turn OFF and check drive circuit.
Turn off power.
0005
Drive unit is overheated. Please 
turn OFF and check drive circuit.
Temperature of drive circuit is higher than 
80°C (176°F). Turn off power.
0007
Bypass/clutch drive error. Please 
turn OFF and check drive circuit.
Bypass/clutch error. Turn off power.
0009
Bypass/clutch is overloaded. 
Please turn OFF and check drive 
circuit.
Bypass/clutch overload. Turn off power.
Error 
no.
Error message
Meaning, remedy