3-1
3. Initial Settings
3.1 NMEA Setting
NMEA port
1. Press the [MENU] key.
2. Press the software key labeled "CONFIGURATION".
3. Press the software key labeled "SETUP NMEA PORT1".
4. Select "FORMAT" by the arrow key.
5. Press the software key labeled "EDIT" to display the following message.
FORMAT
NMEA 0183
   VER 1.5
OUTPUT FORMAT
     
NMEA0183  Ver1.5
NMEA0183  Ver2.0
DGPS 3D
SETUP
  PORT 1
ENTER
CANCEL
Figure 3-1 Output Format display, NMEA port
6. Select NMEA version desired by the arrow key.
7. Press the software key labeled "ENTER".
8. Press the [PLOT] key to finish.