Specifications
The information contained in this section is subject to change without notice. See your
product’s technical datasheet at www.schneider-electric.com for the most current and
complete specifications.
product’s technical datasheet at www.schneider-electric.com for the most current and
complete specifications.
For installation and wiring information, refer to the meter installation sheet.
Related topics
•
See “MID compliance” on page 143 for specifications relevant to the Measuring
Instruments Directive (MID).
Instruments Directive (MID).
Mechanical
Electrical
Mechanical characteristics
Integrated display
model
(PM5560, PM5561)
model
(PM5560, PM5561)
IP degree of protection
(IEC 60529)
(IEC 60529)
Front display: IP52
Meter body: IP30 (except connectors)
Connectors: IP20 with terminal covers installed, IP10
without terminal covers.
Meter body: IP30 (except connectors)
Connectors: IP20 with terminal covers installed, IP10
without terminal covers.
IP rating
Front display: UL Type 12
Panel thickness
6.0 mm (0.25 in) maximum
Gasket thickness
1.0 mm (0.04 in)
Mounting position
Vertical
Display type
Monochrome graphics LCD, 128 x 128 resolution
Display backlight
White LED
Viewable area
67 x 62.5 mm (2.64 x 2.46 in)
Keypad
4 button
Front panel LED indicators
Green LED (heartbeat / communications activity)
Amber LED (active alarm indicator or energy pulse output)
Amber LED (active alarm indicator or energy pulse output)
DIN rail mount model
(PM5563)
(PM5563)
IP degree of protection
(IEC 60529)
(IEC 60529)
Meter body: IP30 (except connectors)
Connectors: IP20 with terminal covers installed, IP10
without terminal covers.
Connectors: IP20 with terminal covers installed, IP10
without terminal covers.
Mounting position
35 mm DIN rail
LED indicators (top)
Amber LED (active alarm indicator / energy pulsing
Green LED (heartbeat / communications activity)
Green LED (heartbeat / communications activity)
Electrical characteristics
Type of measurement
True RMS up to the 63rd harmonic on three-phase (3P,
3P + N)
128 samples per cycle, zero blind
3P + N)
128 samples per cycle, zero blind
Measurement
accuracy
accuracy
IEC 61557-12
PMD/[SD|SS]/K70/0.2
Active energy
±0.2%
Class 0.2S, as per IEC 62053-22
Class 0.2S, as per IEC 62053-22
Reactive energy
±2%
Class 2, as per IEC 62053-23
Class 2, as per IEC 62053-23
Active power
±0.2% as per IEC 61557-12
Reactive power
±1% as per IEC 61557-12
Apparent power
±0.5% as per IEC 61557-12
Current (5 A nominal, per
phase)
phase)
±0.15%
Voltage (L-N)
±0.1%
Frequency
±0.05%