Cleveland Range PDW-4 Prospecto

Descargar
Página de 2
WALL MOUNTED
LOW-CABINET TYPE
1” IPS common drain.
Do not connect other units
to this drain.
Do not use PVC pipe for
drain.
(NOT TO SCALE)
SECT.
VI
PAGE 
10
0707
Litho in U.S.A.
Each compartment has capacity for:
Eight,
12˝ x 20˝ x 2
1
2
˝
Cafeteria Pans or
Six,
12˝ x 20˝ x 4˝
Cafeteria Pans or
Four,
12˝ x 20˝ x 6˝
Cafeteria Pans or
Four,
18˝ x 26˝
Bun Pans
Many regional, state and local codes exist and it is
the   responsibility of the owner and installer to com-
ply with those codes.
Cleveland Range equipment is built to comply with
applicable standards for manufacturers. Included
among those approval agencies are: UL, ULC, NSF,
and CSA.
WATER QUALITY REQUIREMENT
The recommended minimum water quality standards
whether untreated or pre-treated, based upon 10 hours
of use per day, and a Daily Blowdown, are as follows:
TOTAL DISSOLVED SOLIDS less than 60 parts per million
TOTAL ALKALINITY
less than 20 parts per million
SILICA
less than 13 parts per million
pH FACTOR
greater than 7.5
CHLORINE
less than 30 parts per million
Consult a local water treatment specialist for an on site
water analysis for recommendations concerning steam
generator feed water treatment (if required), in order to
remove or reduce harmful concentrations of minerals.
The use of highly mineralized water will mean that more
frequent servicing of the steam generator will be 
necessary. The fact that a water supply is potable is not
proof that it will be suitable for the generator.
Cleveland Range reserves right of design improvement or modification, as warranted.
Right - 3”, Left - 3”, Rear - 3”  
(12” on control side if
adjoining wall or equipment
is over 30” high for service
access)
Contact factory for 
variances to clearances.