Smeg SA9058X Manual De Usuario

Descargar
Página de 24
 
 
Instructions for the installer 
 
11
 
 
 
 
4  ADAPTATION TO DIFFERENT GAS TYPES 
 
 
 
Before carrying out any procedure, cut the electrical supply to the appliance.
 
 
 
 
 
 
 
  The cooking range hob is set to use natural  gas G20/G25 (2E+) at a pressure of 20/25 mbars in 
cooking ranges with a large oven, and butane/propane gas  G30/G31 (3+) at a pressure of 28/37 
mbars in cooking ranges provided with a cylinder housing. Moreover, the guide eye of the hose must 
be replaced with the appropriate one provided. If other types of gas are used, the burner injectors 
must be replaced, then the minimum flame must be adjusted on the gas taps. To replace the 
injectors, follow the instructions set out below. 
 
   
 
 
4.1  Replacing the hob injectors 
 
 
 
 
 This process does not require the 
primary air supply to be adjusted. 
1.
  Remove the racks, take out all 
flame spreaders and caps; 
2.
  use a 7-mm tubular spanner to 
unscrew the burner injectors; 
3.
  replace the burner injectors 
according to the gas to be used 
and as described in paragraph 
“3.2/3.3 Tables of burner and 
injector characteristics”. 
4.
  Put the burners back into their 
housings correctly.