Thermador PCG36 Instruccion De Instalación

Descargar
Página de 56
English 10
All Installer supplied parts must conform to Local Codes.
*15 Amp 120 VAC electrical supply is required for 36" and 48" models with an electric griddle. 
Step 3: Unpacking, Moving, Placing and 
Anchoring the Cooktop
CAUTION
Proper equipment and adequate manpower 
must be used in moving the appliance to avoid 
damage and/or personal injury. The unit is 
heavy and should be handled accordingly.
Important
Verify that the appliance is correct for the type of gas 
being provided. Refer to Step 4 before proceeding with 
the installation. 
Attach the backguard before sliding the appliance into 
the final installed position. See Step 6. 
Remove the outer carton and packing material from the 
shipping base. Ensure that you have all cooktop 
components before proceeding.
Remove the top grate castings and burner caps to 
reduce cooktop’s weight.
NOTE:
Leave adhesive-backed foam layer over brushed-metal 
surfaces, to protect finish from scratches, until the cooktop 
is installed in its final position.
Lift and place the cooktop in the opening. Be careful 
not to pinch the power cord or gas inlet. Care should be 
used not to scratch the griddle cooking plate. 
Make sure that the power cord is free and hanging 
loose.
The cooktop must be level for proper performance.
Replace the cooking grates and burner caps. Ensure 
that the burner caps are correctly seated on the burner 
bases.
Griddle Tilt Adjustment (not all models)
Check the griddle adjustment by pouring two tablespoons 
of water on the back of the griddle plate. The water should 
slowly roll into the grease tray. If not, adjust the two screws 
under the back of the plate. Start with one half turn counter-
clockwise (CCW) of the screws. Further adjustment should 
be made by one-quarter turn until water slowly flows into 
the grease tray. 
 Figure 9: Bottom of Unit
Product Rating
Label/Serial Tag
Threading compounds must be 
resistant to Propane Gas
 1/2" NPT
gas flow
3/4” flex line
3” Min.
Power
Cord or 
Conduit
A manual valve must be installed 
external to the appliance, in an acces-
sible location from the front, for the 
purpose of shutting off the gas supply. 
3-Prong grounding type receptacle 
connected to a properly grounded and 
polarized electrical supply rated at 120VAC, 
10 Amps, (or 15A*)  Single Phase, 60 HZ.