COMPRESSORS: 
 
The VM2, and VM7 has a single hermetic compressor.  The VM12 and VM18 each have two hermetic 
compressors that start in two steps with a delay of 10 seconds to reduce the in-rush of current to the unit. 
 
CONDENSERS: 
  
The  VM  7,  12,  and  18  units  incorporate  a  "maintenance  free"  condenser  design  in  the  refrigeration 
system  which  reduces  the  need  for  the  regular  cleaning  process  that  fin  and  tube  condensers  require. 
Besides  the  savings  in  preventive  maintenance  costs,  energy  expenses  will  be  stable  throughout  long 
periods  of  time  since  the  condensers  will  remain  "clean  and  unobstructed".    The  VM2  condenser 
requires frequent cleaning similar to most commercial refrigerators. 
 
 
EVAPORATOR: 
  
In the event it is believed that the unit has had a “freeze up” condition due to operation of the unit in 
high  temperature  or  humidity  conditions  the  evaporator  can  be  inspected  by  removing  the  floor  of  the 
inside  of  the  unit.    In  the  event  the  evaporator  is  frozen,  it  can  be  thawed  by  emptying  the  cabinet  of 
product and removing power until the coil is clear. 
 
CONDENSATION EVAPORATOR TRAY: 
  
When  the  equipment  operates,  condensed  water  from  the  environment  is  collected  on  the  evaporator. 
During each off-cycle, the water drains to the evaporator tray located at the bottom of the unit where it is 
evaporated using the heat from the refrigeration system. 
  
SLIDING CONDENSING UNIT: 
  
The  condensing  unit  can  be  pulled  out,  sliding  it  approximately  40  cm  (16")  to  allow  servicing  the 
condenser motor(s), compressor(s) and electrical  components.  In order to service the condensing unit, 
remove the two screws that hold the lower front grill (one at each side). Remove the screws that hold the 
front bracket that clasps the condensing unit and slide it gently out to have access to the components you 
want to check. 
  
Once completed, every component must be returned to its original location for proper operation. 
 
LIGHTING: 
  
The lamp can be turned off with the switch located at the left side of the upper section, near the lamp. 
 
NIGHT CURTAIN: 
 
The night curtain should be pulled closed whenever the unit is not required for the active merchandising 
of product.