and turn the needle to the desired temperature using your fingers. Replace the 
lens cover and recheck the calibration. 
DIGITAL THERMOMETER 
For a digital thermometer, note how many degrees the digital display needs to be 
increased or decreased. Press twice directly on the mylar display towards the right 
center using your finger. After pressing the first time, the display should read "cal" 
indicating that you are in the calibration mode and after pressing the second time, 
the display should read either zero or a positive number or a negative number (this 
number is the point of origin for calibration). If your digital display needed to be 
increased, you 
 
Must advance the point of origin by that many degrees by pressing directly on the 
mylar display towards the left top. If your digital display needed to be decreased, 
you must decrease the point of origin by that many degrees by pressing directly on 
the mylar display towards the left bottom. Once calibration is complete, return to 
normal temperature mode by pressing once again on the mylar display towards 
the right center. Now, recheck the calibration. 
Example: the digital display reads 7`c and the internal thermometer reads 4`c so, 
the digital display must be increased by 3`. Press the right center of the display 
twice and the number -1 is displayed (this is the point of origin and could have 
been any number). Now, press the top left of the display three times to make the -
1 go to +2. Calibration is complete so press the right center of the display to return 
to normal temperature mode. 
 
 