Graco PR70 Manual De Usuario
Miscellaneous Assemblies
312393G
43 of 50
Miscellaneous Mechanical Assemblies
Figure 54: PR70 Power Entry Bracket Assembly (LC0106)
Key:
Ref P/N
Description
QTY
Ref P/N
Description
QTY
1
119912
SCREW, PAN, M3X6, PHILLIPS, SS
3
11
84/0130-26/11
LABEL, PE
1
2
121018
ELBOW, SWVL, 3/8 X ¼ NPT, FXM, 90DE
1
12
LC0034
HARNESS, WIRE, REMOTE SIGNAL
1
3
120876
PWR SUPPLY, 24VDC, 40W, 100-240VAC IN
1
13
121178
VALVE, LOCKOUT, ¼ NPT
1
4
120882
FILTER, 1/4NPT
1
14
121179
QUIKCLAMP, ¼ NPT
2
5
120883
NUT, HEX, 7/8-14, MS
1
15
121180
MULTIPORT, [3] ¼ NPT
1
6
120910
PWR ENTRY, 120/240VAC, DUAL FUSE, EMI
1
16
94/0762/99
VALVE, RELIEF, ¼ NPT, M, 110PSI, SIL
1
7
120916
SCREW,FHSC, M3X0.5 X 10, SS
2
17
94/0430/99
PLUG, SKT HD, ¼ NPT, MS
2
8
120993
NUT, HEX, M5X0.8, WITH STAR WASHER
2
18
81/1054-4/11
FUSE 5X20MM, 4AMP, FAST, TYPE F, 250VAC
2
9
15K798
BRACKET, SWITCH, AIR
1
19
LC0031
CABLE ASSY, POWER IN
1
10 15K800 FITTING,
BULKHEAD
1
To Replace the Fuses:
1. Remove the machine fuse holder from the PWR
Entry module (6) by inserting a flat-head
screwdriver between the holder and the back the
PWR Entry module (The fuse holder is above
where AC power is connected to the machine).
screwdriver between the holder and the back the
PWR Entry module (The fuse holder is above
where AC power is connected to the machine).
2. Replace the blown fuse(s) (18) into the fuse holder.
3. Re-install the holder into the PWR Entry Module.