Graco PR70 Manual De Usuario

Descargar
Página de 50
Technical Data 
 
312393G 
 
48 of 50 
Technical Data 
Category 
Data
Metering Pump Effective Area 
80 – 960 mm
2
 (0.124 – 1.49 in
2
) per side
Small Air Cylinder Effective Area 
4560 mm
2
 (7.07 in
2
)
Large Air Cylinder Effective Area 
10260 mm
2
 (15.9 in
2
)
Maximum Stroke Length 
38.1 mm (1.50 in)
Minimum Stroke Length 
5.8 mm (0.23 in)
Volume per Cycle 
2 – 70 cc (0.12 – 4.3 in
3
)
Pump Cycles per 1L (0.26 gal) 
500 – 14.3
Ratios (fixed) 
1:1 to 12:1 (depending upon cylinders selected)
Maximum Fluid Working Pressure 
3000 psi (20.7 MPa, 207 bar)
Maximum Air Input Pressure 
100 psi (0.7 MPa, 7 bar)
Maximum Cycle Rate 
30 cpm
Maximum Operating Temperature 
70 C (160 F), nylon pistons 50 C (120 F) UHMWPE pistons or PE Tanks
Air Inlet Size 
¼ NPT (f)
Pump Fluid Outlet Size 
-03, -04, -06, -08 or –12 JIC fittings for 3/16 in (4.8 mm), ¼ in (6.4 mm), 3/8 in 
(9.5 mm), ½ in (12.7 mm), ¾ in (19.1 mm) hoses
Wetted Parts 
303/304, 17-4 PH, hard chrome, Chromex, carbide, Chemical Resistant 
O-rings, PTFE, nylon, UHMWPE
Weight 
55 kg (120 Lbs) typical with two 7.5L tanks
150 kg (330 Lbs) typical with two 60 L tanks
Sound Power Level 
4 in Air Cylinder 
Measured Per ISO Standard 9614-2 
 100 psi/30 cpm - 81 dBA
50 psi/15cpm – 77 dBA
Compressed Air 
< 10 scfm typical (varies with cycle times)
Electrical Power 
100-240 V 50/60Hz, 1 phase for machine – 80 Watts
208-240V 50/60Hz, 1 phase for heat – 11 kW max.
120 or 240 VAC 50/60Hz 1 phase for on-board agitators, 80 Watts
240 VAC 50/60Hz 1 phase for off-board agitators, 830 Watts