Graco PR70 Manual De Usuario
![Graco](https://files.manualsbrain.com/attachments/1319162103b48ca2e3bc8be98dc4af49773243eb/common/fit/150/50/e6af184f1da33ce12e7a4ef94157d351fbcc741ef980bf1190a6d2679721/brand_logo.jpeg)
Technical Data
312393G
48 of 50
Technical Data
Category
Data
Metering Pump Effective Area
80 – 960 mm
2
(0.124 – 1.49 in
2
) per side
Small Air Cylinder Effective Area
4560 mm
2
(7.07 in
2
)
Large Air Cylinder Effective Area
10260 mm
2
(15.9 in
2
)
Maximum Stroke Length
38.1 mm (1.50 in)
Minimum Stroke Length
5.8 mm (0.23 in)
Volume per Cycle
2 – 70 cc (0.12 – 4.3 in
3
)
Pump Cycles per 1L (0.26 gal)
500 – 14.3
Ratios (fixed)
1:1 to 12:1 (depending upon cylinders selected)
Maximum Fluid Working Pressure
3000 psi (20.7 MPa, 207 bar)
Maximum Air Input Pressure
100 psi (0.7 MPa, 7 bar)
Maximum Cycle Rate
30 cpm
Maximum Operating Temperature
70 C (160 F), nylon pistons 50 C (120 F) UHMWPE pistons or PE Tanks
Air Inlet Size
¼ NPT (f)
Pump Fluid Outlet Size
-03, -04, -06, -08 or –12 JIC fittings for 3/16 in (4.8 mm), ¼ in (6.4 mm), 3/8 in
(9.5 mm), ½ in (12.7 mm), ¾ in (19.1 mm) hoses
Wetted Parts
303/304, 17-4 PH, hard chrome, Chromex, carbide, Chemical Resistant
O-rings, PTFE, nylon, UHMWPE
Weight
55 kg (120 Lbs) typical with two 7.5L tanks
150 kg (330 Lbs) typical with two 60 L tanks
Sound Power Level
4 in Air Cylinder
Measured Per ISO Standard 9614-2
4 in Air Cylinder
Measured Per ISO Standard 9614-2
100 psi/30 cpm - 81 dBA
50 psi/15cpm – 77 dBA
Compressed Air
< 10 scfm typical (varies with cycle times)
Electrical Power
100-240 V 50/60Hz, 1 phase for machine – 80 Watts
208-240V 50/60Hz, 1 phase for heat – 11 kW max.
120 or 240 VAC 50/60Hz 1 phase for on-board agitators, 80 Watts
240 VAC 50/60Hz 1 phase for off-board agitators, 830 Watts