If a value specifying a length (other than zero) that does not match the data format on the disk
media is specified in the “Transfer byte length” field in the CDB, that command is terminated with
a CHECK CONDITION status without data being transferred to the INIT.  The sense data at this
time indicate the following contents and the INIT can determine the correct “Transfer byte length”
from their contents.
x  Sense Key
: 05 = ILLEGAL REQUEST
x  Sense Code/Sub-sense Code : 24-00 = Invalid field in CDB
x  “VALID” Bit
: “1”
x  “ILI” bit
: “1”
x  Information Field : (“Transfer byte length in the CDB) – (Original “Transfer byte length”)
Remark
The calculation formula for the information field expresses 1 logical data block as n
physical sectors and n sub-sectors, and when negative, as a complement of 2.
Error recovery processing during execution of this command is performed in accordance with the
specifications in the MODE SELECT parameters (Page code 1:  Read/Write Error Recovery
Parameter, Page Code 21:  Additional Error Recovery Parameter, but the AWRE flag and DTE