VENTING   REQUIREMENTS
Determine which venting method is best for your application.  
Ductwork can extend either through the wall or the roof.
The length of the ductwork and the number of elbows should 
be kept to a minimum to provide efficient performance.  The 
size of the ductwork should be uniform.  Do not install two 
elbows together.  Use duct tape to seal all joints in the ductwork 
system.  Use caulking to seal exterior wall or floor opening 
around the cap.
Flexible ductwork is not recommended. Flexible ductwork 
creates  back  pressure  and  air  turbulence  that  greatly 
reduces performance.
Make sure there is proper clearance within the wall or floor 
for exhaust duct before making cutouts.  Do not cut a joist or 
stud unless absolutely necessary.  If a joist or stud must be 
cut, then a supporting frame must be constructed.  
FOR MORE SPECIFIC DUCTWORK INFORMATION, GO 
TO PAGE 5.
WARNING - To Reduce The Risk Of Fire, Use Only Metal 
Ductwork.
ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz AC-only electrical supply is required on a 
separate 15 amp fused circuit.  A time-delay fuse or circuit 
breaker is recommended.  The fuse must be sized per local 
codes in accordance with the electrical rating of this unit as 
specified  on  the  serial/rating  plate  located  inside  the  unit 
near the field wiring compartment.  THIS UNIT MUST BE 
CONNECTED  WITH  COPPER  WIRE  ONLY.    Wire  sizes 
must conform to the requirements of the National Electrical 
Code, ANSI/NFPA 70 - latest edition, and all local codes and 
ordinances.  Wire size and connections must conform with the 
rating of the appliance.  Copies of the standard listed above 
may be obtained from: 
 
National Fire Protection Association
 
Batterymarch Park
 
Quincy, Massachusetts  02269
This  appliance  should  be  connected  directly  to  the  fused 
disconnect (or circuit breaker) through flexible, armored or 
nonmetallic sheathed copper cable.  Allow some slack in the 
cable so the appliance can be moved if servicing is ever nec-
essary.  A UL Listed, 1/2" conduit connector must be provided 
at each end of the power supply cable (at the appliance and 
at the junction box)
• Venting system MUST terminate outside the 
home.
• DO NOT terminate the ductwork in an attic or 
other enclosed space.
• DO NOT use 4" laundry-type wall caps.
• Flexible-type ductwork is not recommended.
• DO NOT obstruct the flow of combustion and 
ventilation air.
• Failure to follow venting requirements may result 
in a  fire.
When making the electrical connection, cut a 1   1/4" hole 
in the wall.  A hole cut through wood must be sanded until 
smooth.  A hole through metal must have a grommet. 
WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC 
SHOCK, do not use this fan with any solid-state speed 
control device.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI-
CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE 
FOLLOWING:  Use this unit only in the manner intended 
by the manufacturer.  If you have any questions, contact 
the manufacturer.
Before servicing or cleaning unit, switch power off at 
service panel and lock the service disconnecting means 
to prevent power from being switched on accidentally.  
When the service disconnecting means cannot be locked, 
securely fasten a prominent warning device, such as a 
tag, to the service panel.
CAUTION:  For  General  Ventilating  Use  Only.    Do  Not 
Use To Exhaust Hazardous  or  Explosive Materials and 
Vapors.
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRI-
CAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE 
FOLLOWING: Installation Work And Electrical Wiring Must 
Be Done By Qualified Person(s) In Accordance With All 
Applicable Codes And Standards, Including Fire-Rated 
Construction.  
Sufficient  air  is  needed  for  proper  combustion  and 
exhausting of gases through the flue (chimney) of fuel 
burning equipment to prevent backdrafting.  Follow the 
heating equipment manufacturer's guideline and safety 
standards such as those published by the National Fire 
Protection Association (NFPA), and the American Society 
for Heating, Refrigeration and Air Conditioning Engineers 
(ASHRAE), and the local code authorities.
When cutting or drilling into wall or ceiling, do not dam-
age electrical wiring and other hidden utilities.
Ducted fans must always be vented to the outdoors.
   WARNING
• Electrical ground is required on this rangehood.
• If cold water pipe is interrupted by plastic, 
nonmetallic gaskets or other materials, DO NOT 
use for grounding.
• DO NOT ground to a gas pipe.
• DO NOT have a fuse in the neutral or grounding 
circuit.  A fuse in the neutral or grounding circuit 
could result in electrical shock.
• Check with a qualified electrician if you are in doubt 
as to whether the rangehood is properly grounded. 
• DO NOT use this appliance with any solid state fan 
speed control device.
• Failure to follow electrical requirements may result 
in a fire.   
   WARNING
For residential use only.
!
!