Faber 630006504 Prospecto

Descargar
Página de 2
* it is highly recommended that 
professional style cooking always 
be vented to the outside.
upper
chimney
cover
ductless
lower
chimney
cover
canopy
cabinet base
x = distance from hood to cooktop
(varies depending on installation)
min - 24”, suggested max - 30”
also consult cooktop
manufacturer's recommendation
  8 
3/8” 
min
15 
3/8” 
max
23 
5/8”
36”
x
min & max ceiling height examples
x = 30"
min
8' 
6 23/32"
max
9' 
1 23/32"
x = 28"
min
8' 
4 23/32"
max
8' 
11 23/32"
x = 26"
min
8' 
2 23/32"
max
8' 
9 23/32"
x = 24"
min
8' 
23/32"
max
8' 
7 23/32"
12 
1/2"
23/32”
3
 1/2”
upper
chimney
cover
lower
chimney
cover
canopy
cabinet base
x = distance from hood to cooktop
(varies depending on installation)
min - 24”, suggested max - 30”
also consult cooktop
manufacturer's recommendation
  2 
3/4”
  min
15 
3/8”
 max
23 
5/8”
23/32”
36”
x
min & max ceiling height examples
x = 30"
min
8' 
1 3/32"
max
9' 
1 23/32"
x = 28"
min
7' 
11 3/32"
max
8' 
11 23/32"
x = 26"
min
7' 
9 3/32"
max
8' 
9 23/32"
x = 24"
min
7' 
7 3/32"
max
8' 
7 23/32"
Rev. 6/08
WARNING!
  
Product specifications are subject to change without notification.  Consult the installation instructions before you begin installing this rangehood.
Dimensional Diagrams
Pre-Planning Your Installation - 
Important: Consult the installation 
instructions before you begin installing this rangehood.
Ductless Installations*
For installations where ductwork is impos-
sible or highly impractical, a Ductless 
Conversion Kit
 is available.  A charcoal 
filter, which attaches under the blower 
assembly, absorbs smoke and odors.  A 
ductless diverter assembly directs the air 
out to a lower chimney with vent grates cut 
into the sides.
Make your ductrun as straight and short as possible.  The ductrun should 
not exceed 35 equivalent feet if ducted with the required minimum of 6” 
round duct.  Count 45º angles as 3 feet, 90º elbows as 5 feet, and 90º flat 
elbows as 12 feet.
For best results, use no more than three 90° elbows. Make sure that 
there is a minimum of 24” of straight duct between elbows if more 
than one is used. Do not install two elbows together. If you must 
elbow right away, do it as far away from the hood’s exhaust opening 
as possible.
 
The ducted Dama Isola chimney can be adjusted for ceilings between 7’ 7 3/32” and 9’ 1 23/32” depending on the distance between the bottom of the 
hood and the cooktop (distance x in above DUCTED diagram).  The ductless Dama Isola chimney can be adjusted for ceilings between 8’ 23/32” and 9’ 
1 23/32” depending on the distance between the bottom of the hood and the cooktop (distance x in above DUCTLESS diagram).  For higher ceiling in-
stallations, the High Ceiling Chimney Kit includes an additional support structure which adds 27 1/2" to the various ceiling heights in the figures above.
Ducted
Ducted
Ductless
Ductless
Pre-Planning Your Installation - 
Important: Consult the installation instructions before you begin installing this rangehood.