10. Place the bottom tab of the blower box into the bottom 
mounting channel.
11. Tilt blower box top tab so it is flush with the vent box panel        
and position it under the top mounting bracket.
12. Slide bracket into the “Z” slots.
13. Tighten the 2 hex/slotted head screws to secure.
14. Place the small vent cover over the hole in the vent box and 
secure in place with the 4 screws.
Complete Installation
1. Attach backdraft damper over 6" vent extension. Secure with 
vent clamp.
2. Remove screw attaching the terminal box cover. 
Determine which direction (rear or bottom) electrical 
connection will need to run from vent system terminal box. 
Remove rear or bottom knockout and install a UL listed or 
CSA approved conduit connector.
3. Insert downdraft vent into countertop cutout. Using 2 or more 
people, position downdraft vent so it is centered in cutout 
and parallel to edge of cutout. Check that downdraft vent is 
level vertically. Then fasten lower support legs to the cabinet 
floor with screws.
A. Blower box
B. Bottom mounting channel
A
B
A. 6" vent extension
B. Backdraft damper
A. Terminal box cover
A
B
A