Bakers Pride FW-15 Manual De Usuario

Descargar
Página de 36
Fry Warmer 
 
Maintenance 
 
 
11 
Troubleshooting 
Refer to the table below for troubleshooting information.  
 
Problem Cause 
Possible 
Solution 
Warmer chute is not 
holding heat 
Ceramic heating 
element failure 
Contact an authorized BKI service agent for 
corrective action. 
Noisy fan 
Fan blade is dirty or fan 
bearings are failing 
Contact an authorized BKI service agent for 
corrective action. 
FW-15/FW-15T/FW-15DTO (Bottom Breather) 
Warmer chute is not 
heating and perforated pan 
is not heating 
No power to unit. 
Make sure that the circuit breaker and switch at the 
power supply are supplying power to the unit. If 
problem persists, contact licensed electrician. 
Warmer chute is heating 
and the perforated pan is 
not heating 
Fan has overheated and 
cut off 
 
Or 
 
Heating coil has failed 
Wipe the dust from the air intake louvers to allow 
proper airflow and prevent fan overheating. Turn 
the power switch off. Wait 60 seconds. Turn the 
power switch back on. 
 
Contact an authorized BKI service agent for 
corrective action. 
FW-12/FW-12T/FW-15 (Side Breather) 
Warmer chute is not 
heating and perforated pan 
is not heating 
No power to unit or main 
switch is off. 
Make sure that the circuit breaker and switch at the 
power supply are supplying power to the unit. If 
problem persists, contact licensed electrician. 
Warmer chute is heating 
and the perforated pan is 
not heating 
Fan has overheated and 
cut off or fan has failed 
 
Or 
 
Heating coil has failed 
Check to see if dust or any other object is blocking 
the air intake. Remove blockage if necessary. If 
problem persists contact an authorized BKI service 
agent for corrective action. 
 
Contact an authorized BKI service agent for 
corrective action. 
 
Repair 
 
 
Before replacing any parts, make sure the power has been turned off and the unit has 
cooled down. 
Lamp Replacement 
 
Only use Teflon-coated lamp to prevent glass contamination. 
 
1.  Make sure power to the unit is OFF and the unit has cooled down.  
 
2.  Carefully remove the faulty lamp.  
 
3.  Replace with the new lamp.