5) Bin Control
CAUTION
When the ambient temperature is below 45°F, the Bin Control Thermostat
operates to stop the icemaker even if the Ice Storage Bin is empty.  When
the Thermostat is set in the prohibited range, the icemaker operates
continuously even if the Ice Storage Bin is filled with ice.  Setting in the
prohibited range might cause severe damage to the icemaker resulting in
failure.
No adjustment is required under normal use, as the Bin Control is factory-adjusted.
Adjust it, if necessary, so that the icemaker stops automatically in approximately 6 to 10
seconds after ice contacts the Bin Control Thermostat Bulb.
[e] CHECKING CONTROLLER BOARD
1) Visually check the sequence with the icemaker operating.
2) Visually check the Controller Board by using the following procedures.
  (i) Adjust the Defrost Timer to minimum position.
Disconnect the Thermistor from the Controller Board.
Connect a 1.5k
W
 - 3.5k
W
 resistor to the Connector K3 (pins #1 and #2), and energize
the unit.
After the 1 minute ± 5 second water supply cycle and the 2 minute ± 10 second defrost
cycle, the unit should start the freeze cycle.
 (ii) After the above step (i), disconnect the Float Switch leads from the Controller Board
within the first 5 minutes of the freeze cycle.
The unit should go into the defrost cycle after the first 5 minutes ± 20 seconds of
the freeze cycle.
(iii)
Reconnect the Float Switch Connector to the Controller Board.  After the first 5
minutes of the freeze cycle, disconnect the Float Switch leads from the Controller
Board.
At this point, the unit should start the defrost cycle.
(iv) After Step (iii), de-energize the unit and confirm that the Defrost Timer is in the
minimum position.  Disconnect the resistor from the Controller Board, and energize
the unit.
After the 1 minute water supply cycle, the defrost cycle starts.
Re-connect a 1.5k
W
 - 3.5k
W
 resistor to the Connector K3 (pins #1 and #2) after
the first 2 minutes of the defrost cycle.