U-Line CLR2060SSHR Manual De Usuario

Descargar
Página de 118
96
Design 
Features 
Performance 
THERMISTOR
The thermistor senses the refrigeration system “high side” temperature. This is used in conjunction with 
the control board to determine the length of the freeze and harvest cycles.
Thermistors generally fail due to moisture or physical damage. U-Line “high side” thermistors are 
encased in a specially-designed, moisture-sealed aluminum block. The thermistor is also mounted to 
the “high side” or “dry” portion of the refrigeration system. This eliminates physical damage and 
moisture concerns.
Check Light on Control Board
The LED light on the control board serves three functions.
1. Steady light -
The control board has power to it and operation is normal.
2. Slow flash -
The control board has detected a sensor problem. This will
happen if the thermistor’s plug is disconnected from the
control board. This will also happen if the thermistor fails open.
3. Rapid flashing - This indicates the control board is receiving a high heat signal from the 
thermistor. This can be caused by a dirty condenser, inadequate air flow 
(unit installed behind closed doors), failed condenser fan motor, etc.
In both the slow flash and rapid flashing situations, the unit will stop operation.
0
1
2
3
4
5
-5
-4
-3
-2
-1
LED Light
UL301
CLR2060 MODEL