Cleveland Range C9797-K2PF Prospecto

Descargar
Página de 2
NOTES:
Cleveland Range reserves right of design improvement or modification, as warranted.
Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes.
Cleveland Range equipment is built to comply with applicable standards for manufacturers.
SECT.
IIB
PAGE 
13
0707
20.50”
521mm
5.16”
131mm
25.50”
521mm
22.44”
570mm
Outlet to 
Combi 
Oven-Steamer
Inlet
3/4” FNPT
Kleensteam II
Prefilter
Technical Data
Overall Dimensions:
25.5”H x 20.5”W x 7”D
Inlet Connection:
3/4” FNPT
Outlet Connection:
3/4” FNPT
Service Flow Rate:
Maximum 3.5 gpm (13.2 Lpm) - twin cartridges
Pressure Requirements:
10 - 125 psi (0.7 – 8.6 bar), non-shock
Maximum Water Temperature at Inlet:  100°F (38°C)
Alkalinity Range:
2 to 12 grains per gallon
Electrical: 
No electrical connection required
Shipping Weight:
34 lbs.
Operating Weight:
42 lbs.
The contaminants or other substances removed or reduced by this
drinking water system are not necessarily in your water. Do not
use with water that is microbiologically unsafe or of unknown
quality without adequate disinfection before or after the system.
Systems certified for cyst reduction may be used with disinfected
water that may contain filterable cysts.
NSF Certified under NSF/ANSI Standard 42 for materials