U-Line B195 Manual De Usuario

Descargar
Página de 19
U-Line Door Panel Installation
13
8 Door Panel Installation
Door Panel Preparation
BI-95, BI-2115B(WH), WH95BTP
A custom door panel may be inserted into the doorframe. Custom 
door panels can be flat or raised, as long as the maximum panel 
thickness, where inserted into the door reveal (channel), is no 
more than 1/4" thick. For raised panels, the depth of the reveal is 
1/4" on all four sides.
IMPORTANT
IMPORTANT
Raised panels will reduce the door’s 90° swing/zero 
clearance if the unit is installed next to a wall or similar 
type of structure.
Panel Dimensions.
The door panel must not weigh more than 20 lbs.
Door Panel Installation (98, SP18, & 
ADA15)
Install the insert as follows:
CAUTION
Use care when handling the insert. Insert edges may be 
sharp.
1. Remove top hinge screw pin with Phillips head screwdriver. 
Remove door by tilting forward and lifting off bottom hinge pin.
2. Pull door gasket out of groove (top edge of door only). Start in 
the middle and pull outward, moving toward the edge . This may 
take some force.
Model
Width
Height
BI-95
12 15/16”
13 15/32”
BI-2115
14 1/32”
27 11/16”
BI95BTP
12 15/16”
13 15/32”
3. Remove the two outside screws holding 
door handle. Slightly separate door 
handle from door.
4. Pull handle up and off.
5. Slide custom door panel insert into 1/4-
inch channel in door front.
IMPORTANT
IMPORTANT
Some units include a magnet on the bottom of the door. 
Use care not to damage magnet, when installing door 
insert. Do not set door on bottom edge when pushing 
insert into place.
6. Holding door gasket out of the way, replace handle on door, 
making sure it is seated properly on insert and that screw holes 
line up.
7. Install two small screws removed in Step 3.
8. Starting at the corners and working inward, push door gasket 
into place on door.
9. Place door on bottom hinge pin and install upper hinge screw.
BI-95
BI-2115
BI95BTP